- Country of Origin:
- France
- Item:
- Safety Controller
- Output Type:
- 2 relays, 2 NO contacts (4 NO total) || solid state, 6, volt-free
- Enclosure Material:
- Plastic
- IP Rating:
- IP20
- Safety Output Configuration:
- 4NO
- Safety Output Ratings:
- 1.5 A @ 24V DC, 2 A @ 24V AC
- Number of Inputs:
- 32
- Features:
- Configurable, Monitoring Multiple Safety Functions
- Height:
- 5.96 in
- Mounting:
- Surface or DIN rail
- Operating Temp.:
- -10 to 55 Degrees C
- Standards:
- CSA, EN 1760-1/ISO 13856-1, EN 574/ISO 13851, EN 954-1/EN/ISO 13849-1, EN/IEC 60204-1, EN/IEC 60947-5-1, EN/IEC 61496-1, IEC 61508, TUV, UL Listed
- Width:
- 2.91 in
- Input Power:
- 24 V DC
- Response Time:
- 30 msec
- Depth:
- 6.02 in
- Safety Module Name:
- XPSMC
- Minimum Output Current:
- 10 mA relay output
- Associated Fuse Rating:
- 16 A gL power supply || 4 A gL relay output || 6 A fast blow relay output
- Ip Degree Of Protection:
- IP20 conforming to EN/IEC 60529
- [Ui] Rated Insulation Voltage:
- 300 V 2)IEC 60647-5-1, DIN VDE 0110 part 1
- [Us] Rated Supply Voltage:
- 24 V DC - 20 to 20 %
- Maximum Line Resistance:
- 100 Ohm <2000 m
- Output Thermal Current:
- 4 A for both outputs simultaneously || 6 A for 1 output and 2 A for the other relay output
- Minimum Output Voltage:
- 17 V relay output
- Safety Use Category:
- category 4 maximum EN 954-1/EN/ISO 13849-1 || PLE maximum EN/ISO 13849-1 || SIL 3 maximum IEC 61508
- Local Signalling:
- 46 LEDs
- Product Certifications:
- CSA || UL || TUV
- Type Of Start:
- configurable
- Method Of Access:
- slave
- Mounting Support:
- mounting plate
- [Ith] Conventional Free Air Thermal Current:
- 16 A relay output || 6.5 A static output circuit
- Power Consumption In W:
- 12 W
- Ambient Air Temperature For Operation:
- -10-55 °C
- Function Of Module:
- dynamic monitoring of hydraulic valves on linear presses || monitoring safety stop at top dead centre on eccentric press || muting function of light curtains || position selector || safety mat monitoring || safety time delays || shaft/chain breaking
- Synchronisation Time Between Inputs:
- depending on configuration selected
- [Uc] Control Circuit Voltage:
- 28.8 V
- Input Protection Type:
- external fuse 16 A
- Breaking Capacity:
- 180 VA holding AC-15 C300 relay output || 1800 VA inrush AC-15 C300 relay output, 2 A 24 V static output circuit || 1.5 A 24 V DC-13)50 ms relay output
- Data Format:
- 1 start bit/8 data bits || 1 stop bit even or odd || 2 stop bits without parity || RTU (Remote Terminal Unit) mode
- Safety Level:
- can reach PL e/category 4 EN 954-1/EN/ISO 13849-1 || can reach SIL 3 IEC 61508
- Parity:
- even Modbus || no Modbus || odd Modbus
- Number Of Addresses:
- 1-247 Modbus
- Exchange Size:
- 14 words
- Communication Port Protocol:
- Modbus 1 RJ45, serial link 1200 bps, 2400 bps, 4800 bps, 9600 bps or 19200 bps
- Supported Modbus Function:
- 01 8-bit output data/32-bit input data || 02 32-bit input data/8-bit output data || 03 information and errors
- Product Or Component Type:
- configurable safety controller
- Ambient Air Temperature For Storage:
- -25-85 °C
- [Uimp] Rated Impulse Withstand Voltage:
- 4 kV III IEC 60647-5-1, DIN VDE 0110 part 1
- Compatible with Series:
- XPCMC
- Overall Height:
- 5.96 in
- Overall Depth:
- 6.02 in
- Operating Temperature - Maximum:
- 131 Degrees F
- Operating Temperature - Minimum:
- 14 Degrees F
- Overall Width:
- 2.91 in
- Package Quantity:
- 1