- Country of Origin:
- France
- Item:
- Overload Relay
- Item - Relay:
- IEC Style Overload Relay
- Use With - Contactors and Starters:
- Mfr. Series LC1D50 to LC1D80 Contactors
- Current Range:
- 48.0 to 65.0A
- Overload Relay Current Range:
- 48 to 65A
- NEMA Size:
- Not Applicable
- Trip Class - Overload:
- 10
- Width:
- 2.95";Number of Poles=3"
- Reset Type - Relay:
- Manual
- Height:
- 4.84";Sensing Method=Thermal"
- Depth:
- 4.76";Overall Height - Relay=4.84 in"
- Standards:
- CSA C22.2 No 60947-4-1, CSA C22.2 No 60947-5-1, EN 50495, EN/IEC 60947-4-1, EN/IEC 60947-5-1, GB/T 14048.4, GB/T 14048.5, REACH, RoHS, UL 60947-4-1, UL 60947-5-1
- Body Width - Relay:
- 2.95 in
- For Use With:
- LC1D50 thru LC1D80 Contactor
- Features:
- Differential
- Trip Class:
- 10A
- Body Height - Relay:
- 4.84 in
- Body Depth - Relay:
- 4.76 in
- Starter Type:
- IEC
- Associated Fuse Rating:
- 4 A gG signalling circuit || 4 A BS signalling circuit
- Ambient Air Temperature For Storage:
- -60-70°C
- Network Frequency:
- 0 to 400 Hz
- Product Or Component Type:
- differential thermal overload relay
- Phase Failure Sensitivity:
- tripping current 130 % of Ir on two phase, the last one at 0
- Climatic Withstand:
- IACS E10
- Product Compatibility:
- LC1D80 || LC1D95
- Device Short Name:
- LRD
- Mounting Support:
- plate, with specific accessories || rail, with specific accessories || under contactor
- Relay Application:
- motor protection
- Control Type:
- Red push-button stop || Blue push-button reset
- [Ith] Conventional Free Air Thermal Current:
- 5 A signalling circuit
- Product Name:
- TeSys LRD || TeSys Deca
- Tightening Torque:
- control circuit 1.7 N.m screw clamp terminals || power circuit 9 N.m screw clamp terminals
- Connections - Terminals:
- power circuit screw clamp terminals 1 4-35 mm² flexible without cable end || power circuit screw clamp terminals 1 4-35 mm² flexible with cable end || power circuit screw clamp terminals 1 4-35 mm² solid without cable end || control circuit screw cla
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947-1
- Tripping Threshold:
- 1.14 +/- 0.06 Ir IEC 60947-4-1
- Permissible Current:
- 0.72 A 500 V AC-15 signalling circuit || 0.06 A 440 V DC-13 signalling circuit
- Ip Degree Of Protection:
- IP20 conforming to IEC 60529
- Dielectric Strength:
- 2.2 kV 50 Hz IEC 60947-1
- [Ui] Rated Insulation Voltage:
- power circuit 1000 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL
- Ambient Air Temperature For Operation:
- -20-60°C without derating IEC 60947-4-1
- [Ue] Rated Operational Voltage:
- 1000 V AC 0 to 400 Hz power circuit IEC 60947-4-1
- Temperature Compensation:
- -20-60°C
- Mechanical Robustness:
- vibrations6 Gn IEC 60068-2-6 || shocks15 Gn for 11 ms IEC 60068-2-7
- Thermal Protection Adjustment Range:
- 48-65 A
- Product Certifications:
- IEC || UL || CSA || CCC || EAC || ATEX INERIS || UKCA
- Range:
- TeSys
- Flame Retardance:
- V1 conforming to UL 94
- Thermal Overload Class:
- class 10A IEC 60947-4-1
- Network Type:
- AC || DC
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Includes Mounting Hardware:
- Not Applicable
- IP Rating:
- IP20
- Compatible with Series:
- TeSys Deca
- Overall Height:
- 3.19 in
- Reset Type:
- Manual
- Minimum Operating Temperature:
- -4 Degrees F
- Overload Protection Type:
- Thermal
- Maximum Voltage Rating:
- 1000V AC
- Auxiliary Contact Form:
- 1NO/1NC
- Body Depth:
- 4.53 in
- Minimum Overload Relay Current Setting:
- 48 A
- Terminal Connection Type:
- Screw Clamp Terminals
- Relay Style:
- IEC
- Maximum Operating Temperature:
- 140 Degrees F
- Body Height:
- 3.19 in
- Body Width:
- 2.76 in
- Mounting Style:
- Direct To Contactor
- Maximum Overload Relay Current Setting:
- 65 A
- Package Quantity:
- 1