- Country of Origin:
- France
- Item:
- Overload Module
- Voltage:
- 110-240V AC/110-220V DC
- Phase:
- Three
- Thermal Setting Range (A):
- 1.25 to 5.00
- For Use With:
- LUxB32, LUxS12, LUxS32 Power Bases, Mfr. Series LUxB12
- Current Range:
- 1.25 to 5.00A
- Number of Poles:
- 3
- Sensing Method:
- Electronic
- Reset Type - Relay:
- Manual
- Features:
- Earth Fault Protection
- Standards:
- ASEFA, ATEX Compliant, CCC, CE, CSA, CSA C22.2, EAC, EN 60947-6-2, Green Premium RoHS/REACH, IEC 60947-6-2, UL Listed
- Trip Class - Overload:
- 10
- Trip Class:
- 10
- Height:
- 66 mm
- Width:
- 45 mm
- Depth:
- 60 mm
- Compatible with Manufacturer Model Number:
- LU2B12FU, LU2B32FU, LU2B38FU, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380
- Terminal Connection Type:
- Wire Leads
- Reset Type:
- Manual
- Minumum Rated Motor Current Adjustment:
- 1.25 A
- Minimum Operating Temperature:
- -13 Degrees F
- Coil Voltage:
- 110-240V AC/DC
- Maximum Operating Temperature:
- 158 Degrees F
- Maximum Rated Motor Current Adjustment:
- 5 A
- Compatible with Series:
- TeSys Ultra
- Maximum Voltage Rating:
- 690V AC
- Safe Separation Of Circuit:
- 400 V SELV between the control and auxiliary circuits IEC 60947-1 || 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
- Typical Current Consumption:
- 280 mA 110 to 240 V AC I maximum while closing with LUB12 || 280 mA 110 to 240 V AC I maximum while closing with LUB32 || 280 mA 110 to 240 V AC I maximum while closing with LUB38 || 280 mA 110 to 220 V DC I maximum while closing with LUB12 || 280 mA
- Vibration Resistance:
- 2 gn 5-300 Hz power poles open IEC 60068-2-6 || 4 gn 5-300 Hz power poles closed IEC 60068-2-6
- Shock Resistance:
- 10 gn power poles open IEC 60068-2-27 || 15 gn power poles closed IEC 60068-2-27
- Resistance To Fast Transients:
- 2 kV 3 serial link IEC 61000-4-4 || 4 kV 4 all circuits except for serial link IEC 61000-4-4
- Function Available:
- protection against overload and short-circuit || earth fault protection || protection against phase failure and phase imbalance || manual reset
- Product Specific Application:
- basic protection and advanced functions, communication
- Control Circuit Voltage:
- 110 to 240 V AC; 110 to 220 V DC
- Non-Dissipating Shock Wave:
- 1 kV serial mode IEC 60947-6-2 || 2 kV common mode IEC 60947-6-2
- Ip Degree Of Protection:
- IP20 front panel and wired terminals IEC 60947-1 || IP20 other faces IEC 60947-1 || IP40 front panel outside connection zone IEC 60947-1
- Load Type:
- 3-phase motor self-cooled
- [Ui] Rated Insulation Voltage:
- 690 V IEC 60947-6-2 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1
- Heat Dissipation:
- 2-2 W control circuit with LUB12 || 3-3 W control circuit with LUB32 || 3-3 W control circuit with LUB38
- Thermal Overload Class:
- class 10 40-60 Hz -25-70°C IEC 60947-6-2 || class 10 40-60 Hz -25-70°C UL 508
- Immunity To Radioelectric Fields:
- 10 V IEC 61000-4-6
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947-6-2
- Main Function Available:
- Protection against overload and short-circuit; Earth fault protection; Protection against phase failure and phase imbalance; Manual reset
- Fire Resistance:
- 960°C parts supporting live components IEC 60695-2-12 || 650°C IEC 60695-2-12
- Motor Power Kw:
- 1.5 kW 400 to 440 V AC 50/60 Hz || 2.2 kW 500 V AC 50/60 Hz || 3 kW 690 V AC 50/60 Hz
- Fixing Mode:
- plug-in front face)
- Thermal Protection Adjustment Range:
- 1.25-5 A
- [Ue] Rated Operational Voltage:
- 690 V AC
- Range:
- TeSys
- Compatibility Code:
- LUCB
- Reset:
- manual reset
- [Uc] Control Circuit Voltage:
- 110 to 240 V AC || 110 to 220 V DC
- Network Frequency:
- 40 to 60 Hz
- Device Short Name:
- LUCB
- Control Circuit Voltage Limits:
- 88 to 264 V AC 110 to 240 V in operation || 88 to 242 V DC 110 to 220 V in operation || 55 V AC 110 to 240 V drop-out || 55 V DC 110 to 220 V drop-out
- Ambient Air Temperature For Storage:
- -40-85°C
- Product Certifications:
- CE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine
- Tripping Threshold:
- 14.2 x Ir +/- 20 %
- Phase Failure Sensitivity:
- yes
- Operating Altitude:
- 6561.68 ft (2000 m)
- Rated Motor Current Adjustment Range:
- 1.25 to 5 A
- Rated Insulation Voltage:
- 690 V IEC 60947-6-2; 600 V UL 60947-4-1; 600 V CSA C22.2 No 60947-4-1
- Operating Time:
- 35 ms opening with LUB12 control circuit || 35 ms opening with LUB32 control circuit || 35 ms opening with LUB38 control circuit || 50 ms closing with LUB12 control circuit || 50 ms closing with LUB32 control circuit || 50 ms closing with LUB38 contr
- Protective Treatment:
- TH IEC 60068
- Product Name:
- TeSys Ultra
- Product Or Component Type:
- advanced control unit
- Resistance To Electrostatic Discharge:
- 8 kV 3 in open air IEC 61000-4-2 || 8 kV 4 on contact IEC 61000-4-2
- Immunity To Voltage Dips:
- 70 % / 500 ms IEC 61000-4-11
- Resistance To Radiated Fields:
- 10 V/m 3 IEC 61000-4-3
- Device Application:
- motor control || motor protection
- Immunity To Microbreaks:
- 3 ms
- Ambient Air Temperature For Operation:
- -25-70°C
- Utilisation Category:
- AC-41 || AC-44 || AC-43
- Product Compatibility:
- power base LUB12 || power base LUB32 || power base LUB38 || power base LUB120 || power base LUB320 || power base LUB380 || reversing contactor breaker LU2B12FU || reversing contactor breaker LU2B32FU || reversing contactor breaker LU2B38FU
- Compatible with Mfr. Model No.:
- LU2B12FU, LU2B32FU, LU2B38FU, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380
- For Use with Mfr Model Number:
- LU2B12FU, LU2B32FU, LU2B38FU, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380
- Package Quantity:
- 1