Overload Module, 1.25 to 5A, Class 10, 3P - LUCB05FU

Schneider Electric
SKU:
LUCB05FU
|
UPC:
785901222088
Availability:
In Stock

Log in for pricing

(No reviews yet)
Current Stock:
Overload Module, Maximum Rated Motor Current Adjustment 5 A, Minumum Rated Motor Current Adjustment 1.25 A, Coil Voltage 110-240V AC/DC, Compatible with Series TeSys Ultra, Terminal Connection Type Wire Leads, Trip Class 10, Phase Three, Maximum Voltage Rating 690V AC, Reset Type Manual, Standards ASEFA, ATEX Compliant, CCC, CE, CSA, CSA C22.2, EAC, EN 60947-6-2, Green Premium RoHS/REACH, IEC 60947-6-2, UL Listed, Compatible with Grainger Part Number 5AB63, 5AB64, 5AB66, 5AB68
Country of Origin:
France
Item:
Overload Module
Voltage:
110-240V AC/110-220V DC
Phase:
Three
Thermal Setting Range (A):
1.25 to 5.00
For Use With:
LUxB32, LUxS12, LUxS32 Power Bases, Mfr. Series LUxB12
Current Range:
1.25 to 5.00A
Number of Poles:
3
Sensing Method:
Electronic
Reset Type - Relay:
Manual
Features:
Earth Fault Protection
Standards:
ASEFA, ATEX Compliant, CCC, CE, CSA, CSA C22.2, EAC, EN 60947-6-2, Green Premium RoHS/REACH, IEC 60947-6-2, UL Listed
Trip Class - Overload:
10
Trip Class:
10
Height:
66 mm
Width:
45 mm
Depth:
60 mm
Compatible with Manufacturer Model Number:
LU2B12FU, LU2B32FU, LU2B38FU, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380
Terminal Connection Type:
Wire Leads
Reset Type:
Manual
Minumum Rated Motor Current Adjustment:
1.25 A
Minimum Operating Temperature:
-13 Degrees F
Coil Voltage:
110-240V AC/DC
Maximum Operating Temperature:
158 Degrees F
Maximum Rated Motor Current Adjustment:
5 A
Compatible with Series:
TeSys Ultra
Maximum Voltage Rating:
690V AC
Safe Separation Of Circuit:
400 V SELV between the control and auxiliary circuits IEC 60947-1 || 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
Typical Current Consumption:
280 mA 110 to 240 V AC I maximum while closing with LUB12 || 280 mA 110 to 240 V AC I maximum while closing with LUB32 || 280 mA 110 to 240 V AC I maximum while closing with LUB38 || 280 mA 110 to 220 V DC I maximum while closing with LUB12 || 280 mA
Vibration Resistance:
2 gn 5-300 Hz power poles open IEC 60068-2-6 || 4 gn 5-300 Hz power poles closed IEC 60068-2-6
Shock Resistance:
10 gn power poles open IEC 60068-2-27 || 15 gn power poles closed IEC 60068-2-27
Resistance To Fast Transients:
2 kV 3 serial link IEC 61000-4-4 || 4 kV 4 all circuits except for serial link IEC 61000-4-4
Function Available:
protection against overload and short-circuit || earth fault protection || protection against phase failure and phase imbalance || manual reset
Product Specific Application:
basic protection and advanced functions, communication
Control Circuit Voltage:
110 to 240 V AC; 110 to 220 V DC
Non-Dissipating Shock Wave:
1 kV serial mode IEC 60947-6-2 || 2 kV common mode IEC 60947-6-2
Ip Degree Of Protection:
IP20 front panel and wired terminals IEC 60947-1 || IP20 other faces IEC 60947-1 || IP40 front panel outside connection zone IEC 60947-1
Load Type:
3-phase motor self-cooled
[Ui] Rated Insulation Voltage:
690 V IEC 60947-6-2 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1
Heat Dissipation:
2-2 W control circuit with LUB12 || 3-3 W control circuit with LUB32 || 3-3 W control circuit with LUB38
Thermal Overload Class:
class 10 40-60 Hz -25-70°C IEC 60947-6-2 || class 10 40-60 Hz -25-70°C UL 508
Immunity To Radioelectric Fields:
10 V IEC 61000-4-6
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947-6-2
Main Function Available:
Protection against overload and short-circuit; Earth fault protection; Protection against phase failure and phase imbalance; Manual reset
Fire Resistance:
960°C parts supporting live components IEC 60695-2-12 || 650°C IEC 60695-2-12
Motor Power Kw:
1.5 kW 400 to 440 V AC 50/60 Hz || 2.2 kW 500 V AC 50/60 Hz || 3 kW 690 V AC 50/60 Hz
Fixing Mode:
plug-in front face)
Thermal Protection Adjustment Range:
1.25-5 A
[Ue] Rated Operational Voltage:
690 V AC
Range:
TeSys
Compatibility Code:
LUCB
Reset:
manual reset
[Uc] Control Circuit Voltage:
110 to 240 V AC || 110 to 220 V DC
Network Frequency:
40 to 60 Hz
Device Short Name:
LUCB
Control Circuit Voltage Limits:
88 to 264 V AC 110 to 240 V in operation || 88 to 242 V DC 110 to 220 V in operation || 55 V AC 110 to 240 V drop-out || 55 V DC 110 to 220 V drop-out
Ambient Air Temperature For Storage:
-40-85°C
Product Certifications:
CE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine
Tripping Threshold:
14.2 x Ir +/- 20 %
Phase Failure Sensitivity:
yes
Operating Altitude:
6561.68 ft (2000 m)
Rated Motor Current Adjustment Range:
1.25 to 5 A
Rated Insulation Voltage:
690 V IEC 60947-6-2; 600 V UL 60947-4-1; 600 V CSA C22.2 No 60947-4-1
Operating Time:
35 ms opening with LUB12 control circuit || 35 ms opening with LUB32 control circuit || 35 ms opening with LUB38 control circuit || 50 ms closing with LUB12 control circuit || 50 ms closing with LUB32 control circuit || 50 ms closing with LUB38 contr
Protective Treatment:
TH IEC 60068
Product Name:
TeSys Ultra
Product Or Component Type:
advanced control unit
Resistance To Electrostatic Discharge:
8 kV 3 in open air IEC 61000-4-2 || 8 kV 4 on contact IEC 61000-4-2
Immunity To Voltage Dips:
70 % / 500 ms IEC 61000-4-11
Resistance To Radiated Fields:
10 V/m 3 IEC 61000-4-3
Device Application:
motor control || motor protection
Immunity To Microbreaks:
3 ms
Ambient Air Temperature For Operation:
-25-70°C
Utilisation Category:
AC-41 || AC-44 || AC-43
Product Compatibility:
power base LUB12 || power base LUB32 || power base LUB38 || power base LUB120 || power base LUB320 || power base LUB380 || reversing contactor breaker LU2B12FU || reversing contactor breaker LU2B32FU || reversing contactor breaker LU2B38FU
Compatible with Mfr. Model No.:
LU2B12FU, LU2B32FU, LU2B38FU, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380
For Use with Mfr Model Number:
LU2B12FU, LU2B32FU, LU2B38FU, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380
Package Quantity:
1