Molded Case Circuit Breaker, HJL Series, 100A, 3 Pole, 600V AC, 100kA at 240V AC - HJL36100

Square D
SKU:
HJL36100
|
UPC:
785901955962
Availability:
In Stock

Log in for pricing

(No reviews yet)
Current Stock:
Molded Case Circuit Breaker 600V 100A
Country of Origin:
Mexico
Item:
Molded Case Circuit Breaker
Series:
HJL
Amps:
100A
Number of Poles:
3
AC Voltage Rating:
600V AC
Circuit Breaker Type:
Standard
Circuit Breaker Actuator:
Toggle
Circuit Breaker Mounting Style:
Unit Mount
Max. AIR Rating:
100kA at 240V AC
Trip Type:
Thermal Magnetic
Instantaneous Trip:
Fixed
Terminal Connection:
Line/Load Lug
Frame Size:
150A/HJ
Width:
4.12 in
Depth:
4.36 in
Height:
6.4 in
DC Voltage Rating:
250V DC
Max. Wire Size:
3/0 AWG (Cu/Al)
Min. Wire Size:
14 AWG (Cu/Al)
Interrupt Rating:
65 kA at 220/240/480V AC, 35 kA at 380/440/415V AC, 18 kA at 500/525V AC, 20 kA at 250/500V DC, 100 kA at 240V AC, 25 kA at 600V AC
High Amp Trip Setting:
1700 A
Standards:
UL, CSA, NEMA, NOM, CE
Application:
HACR rated Applications; Distribution
Color:
Black
Features:
Mercury Free; PVC Free
Operating Altitude:
Less than 6561.68 ft (2000 m) without derating; 5000 m with derating
Number Of Slots:
2 auxiliary switch OF plug-in); 1 alarm switch SD plug-in); 1 overcurrent trip switch SDE plug-in); 1 voltage release MN or MX plug-in)
Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Power Wire Stripping Length:
0.63 in (16 mm)
Communication Interface:
Modbus; Ethernet
Tightening Torque:
44.25 lbf.in (5 N.m) 0.00 to 0.01 in² (2.5 to 6 mm²) (AWG 14 to AWG 10); 123.91 lbf.in (14 N.m) 0.02 to 0.15 in² (10 to 95 mm²) (AWG 8 to AWG 3/0)
Pollution Degree:
3 IEC 60947-1
Rated Insulation Voltage:
750 V IEC 60947-2
Terminal Identifier:
AL150HD
Local Signalling:
Switched off (OFF) 1 trip indicator green)
Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Network Frequency:
50/60 Hz
Quality Labels:
CE
Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2; 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2; 18 kA 500/525 V AC 50/60 Hz IEC 60947-2; 20 kA 250 V DC IEC 60947-2; 20 kA 500 V DC IEC 60947-2
IP Degree Of Protection:
Front cover IP40 IEC 60529
Circuit Breaker Application:
HACR rated
Ambient Air Temperature For Operation:
28 to 158°F (-2 to 70°C)
Continuous Current Rating:
0.8
Ambient Air Temperature For Storage:
-58 to 185°F (-50 to 85°C)
Breaking Capacity:
100 kA 240 V AC 50/60 Hz UL 489; 65 kA 480 V AC 50/60 Hz UL 489; 25 kA 600 V AC 50/60 Hz UL 489; 20 kA 250 V DC UL 489
Suitability For Isolation:
Yes IEC 60947-2
Utilisation Category:
Category A
Protected Poles Description:
3t
Magnetic Hold Current:
900 A
Device Application:
Distribution
Product Name:
PowerPact H
AWG Gauge:
AWG 14 to AWG 3/0 aluminium/copper terminal
Breaking Capacity Code:
J
Product Certifications:
UL; CSA; NOM
Package Quantity: