Molded Case Circuit Breaker, HGA Series, 60A, 3 Pole, 600V AC, 65kA at 240V AC - HGA36060

Square D
SKU:
HGA36060
|
UPC:
785901795032
Availability:
In Stock

Log in for pricing

(No reviews yet)
Current Stock:
Molded Case Circuit Breaker, 60 A Amps, AC Voltage Rating 600V AC, Max. AIR Rating 65kA at 240V AC, For Use With I Line Panelboards, Series HG, High Amp Trip Setting 1,450 A, Low Amp Trip Setting 800 A, Circuit Breaker Type Standard, Number of Poles 3, DC Voltage Rating 250V DC, Terminal Connection Lug, Trip Type Thermal Magnetic, Phase Three, Instantaneous Trip Fixed, Phase Connection ABC, Frame Size 150A/HG, Circuit Breaker Mounting Style I-Line, Height 9.73 in, Width 4.48 in, Depth 4.8 in
Country of Origin:
Mexico
Item:
Molded Case Circuit Breaker
Series:
HGA
Amps:
60A
Number of Poles:
3
AC Voltage Rating:
600V AC
Circuit Breaker Type:
Standard
Phase:
3
Circuit Breaker Actuator:
Toggle
Circuit Breaker Mounting Style:
I-Line
Max. AIR Rating:
65kA at 240V AC
Trip Type:
Thermal Magnetic
Instantaneous Trip:
Fixed
Terminal Connection:
I-Line, Lug
Phase Connection:
ABC
Frame Size:
150A/HG
Width:
4.12 in
Depth:
4.36 in
Height:
6.4 in
DC Voltage Rating:
250/500V DC
Low Amp Trip Setting:
800 A
Standards:
CE, CSA, IEC, UL listed
High Amp Trip Setting:
1,450 A
Min. Wire Size:
14 AWG
Max. Wire Size:
3 AWG
For Use With:
I Line Panelboards
Interrupt Rating:
65 kA at 220/240V AC, 35 kA at 380/440/415/480V AC, 18 kA at 500/525/600V AC, 20 kA at 250/500V DC
Features:
Mercury Free; PVC Free
Color:
Black
Application:
HACR rated Applications; Distribution
Max. Operating Temp.:
104 Degrees F
Terminal Identifier:
AL150HD
Device Application:
Distribution
Operating Altitude:
Less than 6561.68 ft (2000 m) without derating; 5000 m with derating
Ambient Air Temperature For Storage:
-58 to 185°F (-50 to 85°C)
Mounting Height:
4.5 in (114.30 mm)
Local Signalling:
Switched off (OFF) 1 trip indicator green)
AWG Gauge:
AWG 14 to AWG 3/0 aluminium/copper terminal
Breaking Capacity Code:
G
Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Network Frequency:
50/60 Hz
Breaking Capacity:
65 kA 240 V AC 50/60 Hz UL 489; 35 kA 480 V AC 50/60 Hz UL 489; 18 kA 600 V AC 50/60 Hz UL 489; 20 kA 250 V DC UL 489; 20 kA 500 V DC UL 489
Suitability For Isolation:
Yes IEC 60947-2
Rated Insulation Voltage:
750 V IEC 60947-2
Ambient Air Temperature For Operation:
28 to 158°F (-2 to 70°C)
Pollution Degree:
3 IEC 60947-1
Protected Poles Description:
3t
Magnetic Tripping Current:
1450 A
Tightening Torque:
44.25 lbf.in (5 N.m) 0.00 to 0.01 in² (2.5 to 6 mm²) (AWG 14 to AWG 10); 123.91 lbf.in (14 N.m) 0.02 to 0.15 in² (10 to 95 mm²) (AWG 8 to AWG 3/0)
Rated Service Breaking Capacity:
65 kA 220/240 V AC 50/60 Hz IEC 60947-2; 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2; 18 kA 500/525 V AC 50/60 Hz IEC 60947-2; 20 kA 250 V DC IEC 60947-2; 20 kA 500 V DC IEC 60947-2
Communication Interface:
Modbus; Ethernet
Circuit Breaker Application:
HACR rated
Utilisation Category:
Category A
IP Degree Of Protection:
Front cover IP40 IEC 60529
Power Wire Stripping Length:
0.63 in (16 mm)
Number Of Slots:
2 auxiliary switch OF plug-in); 1 alarm switch SD plug-in); 1 overcurrent trip switch SDE plug-in); 1 voltage release MN or MX plug-in)
Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-3
Product Certifications:
UL; CSA; NOM
Continuous Current Rating:
0.8
Quality Labels:
CE
Product Name:
PowerPact H
Mounting:
Plug In Panelboard
Package Quantity:
1