- Country of Origin:
- France
- Full Load Amps-Inductive:
- 9 A
- Item:
- Miniature IEC Magnetic Contactor
- Full Load Amps-Resistive:
- 20 A
- Action:
- Reversing
- Number of Poles:
- 3
- Coil Volts:
- 240 V AC
- Reversing:
- Yes
- HP @ 1 Phase - 230V:
- 1-1/2
- HP @ 1 Phase - 120V:
- 1/2 hp
- Height:
- 3.54 in
- HP @ 1 Phase - 240V:
- 1 1/2 hp
- HP @ 3 Phase - 208V:
- 2 hp
- Width:
- 3.54 in
- Depth:
- 1.97 in
- HP @ 3 Phase - 575V:
- 5 hp
- HP @ 3 Phase - 240V:
- 3 hp
- Enclosure NEMA Rating:
- No Enclosure
- HP @ 3 Phase - 480V:
- 5 hp
- Aux. Contact Configuration:
- 1NC
- Hz:
- 50/60
- Standards:
- BS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660
- Auxiliary Contact Form:
- 1NC
- Frame / Series / Class / Code:
- TeSys
- NEMA Size:
- Not Applicable
- Series:
- TeSys K
- Overvoltage Category:
- CAT III
- Operating Time:
- 10 to 20 ms (Coil Energisation and NO Closing), 10 to 20 ms (Coil De-Energisation and NO Opening)
- Vibration Resistance:
- 4 G (Contactor Closed), 2 G (Contactor Open)
- Rated Making Capacity:
- 110 A
- Operating Speed:
- 3600 cycles per hr
- Thermal Amperage:
- 20 A (at 50°C Power Circuit), 10 A (at 50°C Signalling Circuit)
- Fire Rating:
- UL 94 V1, NF F 16-101, NF F 16-102
- Net Weight:
- 0.39 kg
- Electrical Durability:
- 0.18 Mcycles (20 A, AC-1, Less than 440 V); 1.3 Mcycles (9 A, AC-3, Less than 440 V); 1.3 Mcycles (9 A, AC-3e, Less than 440 V)
- Features:
- Preassembled with Reversing Power Busbar
- Switching Current:
- 5 mA (Signalling Circuit)
- Rated Short-Time Withstand Current:
- 90 A (at 50°C for 1 s Power Circuit), 85 A (at 50°C for 5 s Power Circuit), 80 A (at 50°C for 10 s Power Circuit), 60 A (at 50°C for 30 s Power Circuit), 45 A (at 50°C for 1 min Power Circuit), 40 A (at 50°C for 3 min Power Circuit), 80 A (For
- Watts Loss:
- 1.3W
- IP Rating:
- IP20
- Max. Operating Watts:
- 2.2 kW (at 220 to 230V AC 50/60 Hz), 4 kW (at 380 to 415VAC 50/60 Hz), 4 kW (at 440V AC 50/60 Hz), 4 kW (at 480V AC 50/60 Hz), 4 kW (at 500 to 600V AC 50/60 Hz), 4 kW (at 660 to 690V AC 50/60 Hz)
- Hold VA:
- 4.5 VA
- Insulation Resistance Range:
- Greater Than 10 MOhms (Signalling Circuit)
- Mechanical Durability:
- 5 Mcycles
- Inrush VA:
- 30 VA
- Rated Insulation Volts:
- 600/690V
- Rated Voltage:
- 690V AC
- Fuse Amps:
- 25 A (Power Circuit), 10 A (Signalling Circuit)
- Control Circuit Voltage Limits:
- Operational
- Shock Resistance:
- 10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open)
- Signalling Circuit Frequency:
- Less Than 400 Hz
- Impedance:
- 3 mOhm
- Mounts On:
- Plate, Rail
- Working Height:
- 6561.68 ft
- Environmental Attributes:
- Mercury Free, Toxic Heavy Metal Free
- Rated Breaking Capacity:
- 110 A @ 415V, 440V, 220 to 230V, 380 to 400 V; 80 A @ 500V; 70 A @ 660 to 690V
- Application:
- Motor Control, Resistive Load
- Switching Voltage:
- 17 V (Signalling Circuit)
- Impulse Withstand Voltage:
- 8 kV
- Tightening Torque:
- 0.8 to 1.3 Nm
- Electrical Connection:
- Screw Clamp Terminals
- NEMA Enclosure Rating:
- No Enclosure
- Electrical Operating Durability:
- 1,300,000, 180,000
- Full Load Current - Inductive:
- 9 A
- Mounting Style:
- DIN Rail, Plate
- Horsepower @ Three Phase - 480V AC:
- 5 hp
- Number of Normally Open Main Contacts:
- 3
- Reversing Capability:
- Reversing
- Resistance Properties:
- Insulation Resistant
- Full Load Current - Resistive:
- 20 A
- Maximum Voltage Rating:
- 690V AC
- Horsepower @ Three Phase - 600V AC:
- 5 hp
- Horsepower @ Single Phase - 240V AC:
- 1 1/2 hp
- Includes Auxiliary Contacts:
- Yes
- Minimum Operating Temperature:
- -13 Degrees F
- Overall Depth:
- 2.24 in
- Frequency:
- 50/60 Hz
- Mechanical Operating Durability:
- 5,000,000
- Coil Voltage:
- 230-240V AC
- Number of Auxillary Contacts:
- 1
- Maximum Operating Temperature:
- 122 Degrees F
- Horsepower @ Single Phase - 120V AC:
- 1/2 hp
- Horsepower @ Three Phase - 208V AC:
- 2 hp
- Overall Height:
- 2.28 in
- Horsepower @ Three Phase - 240V AC:
- 3 hp
- Contactor Style:
- IEC
- Overall Width:
- 3.54 in
- NEMA Enclosure Material:
- Not Applicable
- Terminal Connection Type:
- Screw Clamp Terminals
- Embedded Surge Suppressor:
- No
- Package Quantity:
- 1