Miniature IEC Magnetic Contactor, 3 Poles, 24 V DC, 9 A, Reversing: Yes - LP2K0901BD

Square D
SKU:
LP2K0901BD
|
UPC:
785901832348
Availability:
In Stock

Log in for pricing

(No reviews yet)
Current Stock:
Miniature IEC Magnetic Contactor, Auxiliary Contact Form 1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V DC, Number of Poles 3, Full Load Current - Inductive 9 A, Full Load Current - Resistive 20 A, Reversing Capability Reversing, Overall Height 2.28 in, Overall Width 3.54 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys K, Number of Auxillary Contacts 1, Contactor Style IEC
Country of Origin:
France
Item:
Miniature IEC Magnetic Contactor
Full Load Amps-Inductive:
9 A
Action:
Reversing
Full Load Amps-Resistive:
20 A
Number of Poles:
3
Coil Volts:
24 V DC
Reversing:
Yes
HP @ 1 Phase - 120V:
1/2 hp
HP @ 1 Phase - 230V:
1-1/2
Height:
3.54 in
HP @ 1 Phase - 240V:
1 1/2 hp
HP @ 3 Phase - 208V:
2 hp
Width:
3.54 in
HP @ 3 Phase - 240V:
3 hp
HP @ 3 Phase - 575V:
5 hp
Depth:
2.24 in
HP @ 3 Phase - 480V:
5 hp
Enclosure NEMA Rating:
No Enclosure
Aux. Contact Configuration:
1NC
Hz:
50/60
Auxiliary Contact Form:
1NC
Standards:
BS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660
Series:
TeSys K
NEMA Size:
Not Applicable
Control Circuit Voltage Limits:
Operational
Thermal Amperage:
20 A (at 50°C Power Circuit), 10 A (at 50°C Signalling Circuit)
Impulse Withstand Voltage:
8 kV
Operating Speed:
3600 cycles per hr
Rated Insulation Volts:
600/690V
Rated Short-Time Withstand Current:
90 A (at 50°C for 1 s Power Circuit), 85 A (at 50°C for 5 s Power Circuit), 80 A (at 50°C for 10 s Power Circuit), 60 A (at 50°C for 30 s Power Circuit), 45 A (at 50°C for 1 min Power Circuit), 40 A (at 50°C for 3 min Power Circuit), 80 A (For
Features:
Preassembled with Reversing Power Busbar
Application:
Motor Control, Resistive Load
IP Rating:
IP20
Mounts On:
Plate, Rail
Impedance:
3 mOhm
Switching Voltage:
17 V (Signalling Circuit)
Fuse Amps:
25 A (Power Circuit), 10 A (Signalling Circuit)
Working Height:
6561.68 ft
Shock Resistance:
10 G for 11 ms (on Y axis with Contactor Closed), 15 G for 11 ms (on X and Z axis with Contactor Closed), 6 G for 11 ms (on Y axis with Contactor Open), 10 G for 11 ms (on X and Z axis with Contactor Open)
Rated Voltage:
690V AC
Insulation Resistance Range:
Greater Than 10 MOhms (Signalling Circuit)
Fire Rating:
UL 94 V1, NF F 16-101, NF F 16-102
Operating Time:
30 to 40 ms (Coil Energisation and NO Closing), 10 ms (Coil De-Energisation and NO Opening)
Overvoltage Category:
CAT III
Switching Current:
5 mA (Signalling Circuit)
Tightening Torque:
0.8 to 1.3 Nm
Electrical Connection:
Screw Clamp Terminals
Rated Breaking Capacity:
110 A @ 415V, 440V, 220 to 230V, 380 to 400 V; 80 A @ 500V; 70 A @ 660 to 690V
Environmental Attributes:
Mercury Free, Toxic Heavy Metal Free
Rated Making Capacity:
110 A
Electrical Durability:
0.18 Mcycles (20 A, AC-1, Less than 440 V); 1.3 Mcycles (9 A, AC-3, Less than 440 V); 1.3 Mcycles (9 A, AC-3e, Less than 440 V)
Watts Loss:
3W
Max. Operating Watts:
2.2 kW (at 220 to 230V AC 50/60 Hz), 4 kW (at 380 to 415VAC 50/60 Hz), 4 kW (at 440V AC 50/60 Hz), 4 kW (at 480V AC 50/60 Hz), 4 kW (at 500 to 600V AC 50/60 Hz), 4 kW (at 660 to 690V AC 50/60 Hz)
Mechanical Durability:
5 Mcycles
Vibration Resistance:
4 G (Contactor Closed), 2 G (Contactor Open)
Net Weight:
0.48 kg
Frequency:
50/60 Hz
Overall Width:
3.54 in
Mounting Style:
DIN Rail, Plate
Reversing Capability:
Reversing
Horsepower @ Three Phase - 600V AC:
5 hp
Maximum Operating Temperature:
122 Degrees F
Terminal Connection Type:
Screw Clamp Terminals
Horsepower @ Single Phase - 240V AC:
1 1/2 hp
NEMA Enclosure Rating:
No Enclosure
Horsepower @ Three Phase - 208V AC:
2 hp
Maximum Voltage Rating:
690V AC
Mechanical Operating Durability:
5,000,000
Number of Normally Open Main Contacts:
3
Overall Depth:
2.24 in
Full Load Current - Inductive:
9 A
Resistance Properties:
Insulation Resistant
Number of Auxillary Contacts:
1
Horsepower @ Single Phase - 120V AC:
1/2 hp
Embedded Surge Suppressor:
No
Full Load Current - Resistive:
20 A
Contactor Style:
IEC
Includes Auxiliary Contacts:
Yes
Minimum Operating Temperature:
-13 Degrees F
Electrical Operating Durability:
1,300,000, 180,000
Overall Height:
2.28 in
Coil Voltage:
24V DC
Horsepower @ Three Phase - 480V AC:
5 hp
NEMA Enclosure Material:
Not Applicable
Horsepower @ Three Phase - 240V AC:
3 hp
Auxiliary Contact Composition:
1 NC
Connections - Terminals:
screw clamp terminals 1 0.00 to 0.01 in² (1.5 to 4 mm²)solid; screw clamp terminals 1 0.00 to 0.01 in² (0.75 to 4 mm²)flexible without cable end; screw clamp terminals 1 0.00 to 0.00 in² (0.34 to 2.5 mm²)flexible with cable end; screw clamp ter
Rated Short Time Withstand Current:
90 A 122°F (50°C) - 1 s for power circuit; 85 A 122°F (50°C) - 5 s for power circuit; 80 A 122°F (50°C) - 10 s for power circuit; 60 A 122°F (50°C) - 30 s for power circuit; 45 A 122°F (50°C) - 1 min for power circuit; 40 A 122°F (50°C) -
Associated Fuse Rating:
25 A gG at Less than or Equal to 440 V for power circuit; 25 A aM for power circuit; 10 A gG for signalling circuit conforming to IEC 60947; 10 A gG for signalling circuit conforming to VDE 0660
Operating Altitude:
6561.68 ft (2000 m) without derating
Flame Retardance:
V1 conforming to UL 94; Requirement 2 conforming to NF F 16-101; Requirement 2 conforming to NF F 16-102
Minimum Switching Voltage:
17 V for signalling circuit
Poles Description:
3P
Maximum Operating Rate:
3600 cyc/h
Conventional Free Air Thermal Current:
20 A (at 140°F (60°C)) for power circuit; 10 A (at 122°F (50°C)) for signalling circuit
Power Pole Contact Composition:
3 NO
Product Certifications:
CB Scheme; CCC; UL; CSA; EAC; CE; UKCA
Control Circuit Type:
DC standard
Hold-In Power Consumption in W:
3 W 68°F (20°C)
Heat Dissipation:
3 W
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Device Application:
Control
Insulation Resistance:
Greater than 10 MOhm for signalling circuit
Product Or Component Type:
Reversing contactor
Average Impedance:
3 mOhm - Ith 20 A 50 Hz for power circuit
Rated Insulation Voltage:
Power circuit 600 V UL 508; Power circuit 690 V IEC 60947-4-1; Signalling circuit 690 V IEC 60947-4-1; Signalling circuit 690 V IEC 60947-5-1; Signalling circuit 600 V UL 508; Power circuit 600 V CSA C22.2 No 14; Signalling circuit 600 V CSA C22.2 No
IP Degree Of Protection:
IP20 VDE 0106
Ambient Air Temperature For Storage:
-58 to 176°F (-50 to 80°C)
Non Overlap Distance:
0.02 in (0.5 mm)
Motor Power KW:
2.2 kW 220 to 230 V AC 50/60 Hz; 4 kW 380 to 415 V AC 50/60 Hz; 4 kW 440/690 V AC 50/60 Hz
Utilisation Category:
AC-3; AC-3e; AC-4; AC-1
Mounting Support:
Plate; Rail
IRMS Rated Making Capacity:
110 A AC for power circuit conforming to IEC 60947; 110 A AC for signalling circuit conforming to IEC 60947
Mechanical Robustness:
Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27; Vibrations contactor closed4 Gn, 5 to 300 Hz IEC 60068-2-6; Vibrations contactor opened2 Gn, 5 to 300 Hz IEC 60068-2-6
Minimum Switching Current:
5 mA for signalling circuit
Ambient Air Temperature For Operation:
-13 to 122°F (-25 to 50°C)
Interlocking Type:
Mechanical
Protective Treatment:
TC IEC 60068; TC DIN 50016
Auxiliary Contacts Type:
Instantaneous 1 NC
Rated Operational Voltage:
Power circuit 690 V AC 50/60 Hz; Signalling circuit Less than or Equal to 690 V AC 50/60 Hz
Rated Operational Current:
9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit; 20 A (at Less than 140°F (60°C)) at Less than or Equal to 690 V
Inrush Power in W:
3 W 68°F (20°C))
Contactor Application:
Motor control; Resistive load
Package Quantity:
1