Miniature IEC Magnetic Contactor, 3 Poles, 120 V AC, 6 A, Reversing: Yes - LC2K0601F7

Schneider Electric
SKU:
LC2K0601F7
|
UPC:
785901882848
Availability:
In Stock

Log in for pricing

(No reviews yet)
Current Stock:
Miniature IEC Magnetic Contactor, Auxiliary Contact Form 1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 110V AC, Number of Poles 3, Full Load Current - Inductive 6 A, Full Load Current - Resistive 15 A, Reversing Capability Reversing, Overall Height 2.28 in, Overall Width 3.54 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys K, Number of Auxillary Contacts 1, Contactor Style IEC
Country of Origin:
France
Item:
Miniature IEC Magnetic Contactor
Full Load Amps-Inductive:
6 A
Full Load Amps-Resistive:
15 A
Action:
Reversing
Number of Poles:
3
Coil Volts:
120 V AC
Reversing:
Yes
HP @ 1 Phase - 120V:
1/2 hp
HP @ 1 Phase - 230V:
1-1/2
Height:
3.54 in
HP @ 1 Phase - 240V:
1 1/2 hp
HP @ 3 Phase - 208V:
1 1/2 hp
Width:
3.54 in
Depth:
1.97 in
HP @ 3 Phase - 575V:
3 hp
HP @ 3 Phase - 240V:
1 1/2 hp
Enclosure NEMA Rating:
No Enclosure
HP @ 3 Phase - 480V:
3 hp
Aux. Contact Configuration:
1NC
Hz:
50/60
Standards:
BS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660
Frame / Series / Class / Code:
TeSys
Auxiliary Contact Form:
1NC
NEMA Size:
Not Applicable
Series:
TeSys K
Net Weight:
0.39 kg
Shock Resistance:
10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open)
Overvoltage Category:
CAT III
Inrush VA:
30 VA
IP Rating:
IP20
Signalling Circuit Frequency:
Less Than 400 Hz
Rated Voltage:
690V AC
Electrical Connection:
Screw Clamp Terminals
Features:
Preassembled with Reversing Power Busbar
Vibration Resistance:
4 G (Contactor Closed), 2 G (Contactor Open)
Impulse Withstand Voltage:
8 kV
Electrical Durability:
1.3 Mcycles (6 A, AC-3, Less than 440 V); 1.3 Mcycles (6 A, AC-3e, Less than 440 V)
Environmental Attributes:
Mercury Free, Toxic Heavy Metal Free
Rated Making Capacity:
110 A
Mounts On:
Plate, Rail
Max. Operating Watts:
1.5 kW (at 220 to 230V AC 50/60 Hz), 2.2 kW (at 380 to 415VAC 50/60 Hz), 3 kW (at 440V AC 50/60 Hz), 3 kW (at 480V AC 50/60 Hz), 3 kW (at 500 to 600V AC 50/60 Hz), 3 kW (at 660 to 690V AC 50/60 Hz)
Fuse Amps:
25 A (Power Circuit), 10 A (Signalling Circuit)
Rated Insulation Volts:
600/690V
Switching Voltage:
17 V (Signalling Circuit)
Watts Loss:
1.3W
Fire Rating:
UL 94 V1, NF F 16-101, NF F 16-102
Mechanical Durability:
5 Mcycles
Rated Short-Time Withstand Current:
90 A (at 50°C for 1 s Power Circuit), 85 A (at 50°C for 5 s Power Circuit), 80 A (at 50°C for 10 s Power Circuit), 60 A (at 50°C for 30 s Power Circuit), 45 A (at 50°C for 1 min Power Circuit), 40 A (at 50°C for 3 min Power Circuit), 80 A (For
Operating Speed:
3600 cycles per hr
Rated Breaking Capacity:
110 A @ 415V, 440V, 220 to 230V, 380 to 400 V; 80 A @ 500V; 70 A @ 660 to 690V
Switching Current:
5 mA (Signalling Circuit)
Tightening Torque:
0.8 to 1.3 Nm
Hold VA:
4.5 VA
Working Height:
6561.68 ft
Impedance:
3 mOhm
Operating Time:
10 to 20 ms (Coil Energisation and NO Closing), 10 to 20 ms (Coil De-Energisation and NO Opening)
Thermal Amperage:
20 A (at 50°C Power Circuit), 10 A (at 50°C Signalling Circuit)
Control Circuit Voltage Limits:
Operational
Insulation Resistance Range:
Greater Than 10 MOhms (Signalling Circuit)
Application:
Motor Control
Resistance Properties:
Insulation Resistant
Horsepower @ Three Phase - 600V AC:
3 hp
Minimum Operating Temperature:
-13 Degrees F
Overall Width:
3.54 in
Horsepower @ Three Phase - 240V AC:
1 1/2 hp
Mechanical Operating Durability:
5,000,000
Overall Height:
2.28 in
Includes Auxiliary Contacts:
Yes
Electrical Operating Durability:
1,300,000
Full Load Current - Resistive:
15 A
Full Load Current - Inductive:
6 A
NEMA Enclosure Rating:
No Enclosure
Number of Normally Open Main Contacts:
3
Maximum Voltage Rating:
690V AC
Overall Depth:
2.24 in
Horsepower @ Single Phase - 240V AC:
1 1/2 hp
Horsepower @ Single Phase - 120V AC:
1/2 hp
Coil Voltage:
110V AC
Maximum Operating Temperature:
122 Degrees F
Reversing Capability:
Reversing
Horsepower @ Three Phase - 208V AC:
1 1/2 hp
NEMA Enclosure Material:
Not Applicable
Contactor Style:
IEC
Mounting Style:
DIN Rail, Plate
Frequency:
50/60 Hz
Terminal Connection Type:
Screw Clamp Terminals
Embedded Surge Suppressor:
No
Number of Auxillary Contacts:
1
Horsepower @ Three Phase - 480V AC:
3 hp
Connections - Terminals:
screw clamp terminals 1 0.00 to 0.01 in² (1.5 to 4 mm²)solid; screw clamp terminals 1 0.00 to 0.01 in² (0.75 to 4 mm²)flexible without cable end; screw clamp terminals 1 0.00 to 0.00 in² (0.34 to 2.5 mm²)flexible with cable end; screw clamp ter
Mechanical Robustness:
Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on X axis6 Gn for 11 ms IEC
Poles Description:
3P
Device Application:
Control
Ambient Air Temperature For Storage:
-58 to 176°F (-50 to 80°C)
Associated Fuse Rating:
25 A gG at Less than or Equal to 440 V for power circuit; 25 A aM for power circuit; 10 A gG for signalling circuit conforming to IEC 60947; 10 A gG for signalling circuit conforming to VDE 0660
Mounting Support:
Plate; Rail
Hold-In Power Consumption in VA:
4.5 VA (at 68°F (20°C))
IP Degree Of Protection:
IP20 VDE 0106
Utilisation Category:
AC-3; AC-3e; AC-4
IRMS Rated Making Capacity:
110 A AC for power circuit conforming to IEC 60947; 110 A AC for signalling circuit conforming to IEC 60947
Product Certifications:
CB Scheme; CCC; UL; CSA; EAC; CE; UKCA
Maximum Operating Rate:
3600 cyc/h
Product Or Component Type:
Reversing contactor
Operating Altitude:
6561.68 ft (2000 m) without derating
Auxiliary Contact Composition:
1 NC
Motor Power KW:
1.5 kW 220 to 230 V AC 50/60 Hz; 2.2 kW 380 to 415 V AC 50/60 Hz; 3 kW 440/690 V AC 50/60 Hz
Flame Retardance:
V1 conforming to UL 94; Requirement 2 conforming to NF F 16-101; Requirement 2 conforming to NF F 16-102
Rated Operational Voltage:
Power circuit 690 V AC 50/60 Hz; Signalling circuit Less than or Equal to 690 V AC 50/60 Hz
Heat Dissipation:
1.3 W
Insulation Resistance:
Greater than 10 MOhm for signalling circuit
Non Overlap Distance:
0.02 in (0.5 mm)
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Ambient Air Temperature For Operation:
-13 to 122°F (-25 to 50°C)
Minimum Switching Voltage:
17 V for signalling circuit
Rated Short Time Withstand Current:
90 A 122°F (50°C) - 1 s for power circuit; 85 A 122°F (50°C) - 5 s for power circuit; 80 A 122°F (50°C) - 10 s for power circuit; 60 A 122°F (50°C) - 30 s for power circuit; 45 A 122°F (50°C) - 1 min for power circuit; 40 A 122°F (50°C) -
Control Circuit Voltage:
110 V AC 50/60 Hz
Auxiliary Contacts Type:
Instantaneous 1 NC
Power Pole Contact Composition:
3 NO
Rated Operational Current:
6 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 6 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Protective Treatment:
TC IEC 60068; TC DIN 50016
Average Impedance:
3 mOhm - Ith 20 A 50 Hz for power circuit
Conventional Free Air Thermal Current:
20 A (at 140°F (60°C)) for power circuit; 10 A (at 122°F (50°C)) for signalling circuit
Inrush Power in VA:
30 VA (at 68°F (20°C))
Minimum Switching Current:
5 mA for signalling circuit
Interlocking Type:
Mechanical
Control Circuit Type:
AC 50/60 Hz
Rated Insulation Voltage:
Power circuit 600 V UL 508; Power circuit 690 V IEC 60947-4-1; Signalling circuit 690 V IEC 60947-4-1; Signalling circuit 690 V IEC 60947-5-1; Signalling circuit 600 V UL 508; Power circuit 600 V CSA C22.2 No 14; Signalling circuit 600 V CSA C22.2 No
Package Quantity:
1