- Country of Origin:
- France
- Item:
- Miniature IEC Magnetic Contactor
- Full Load Amps-Inductive:
- 6 A
- Full Load Amps-Resistive:
- 15 A
- Action:
- Reversing
- Number of Poles:
- 3
- Coil Volts:
- 120 V AC
- Reversing:
- Yes
- HP @ 1 Phase - 120V:
- 1/2 hp
- HP @ 1 Phase - 230V:
- 1-1/2
- Height:
- 3.54 in
- HP @ 1 Phase - 240V:
- 1 1/2 hp
- HP @ 3 Phase - 208V:
- 1 1/2 hp
- Width:
- 3.54 in
- Depth:
- 1.97 in
- HP @ 3 Phase - 575V:
- 3 hp
- HP @ 3 Phase - 240V:
- 1 1/2 hp
- Enclosure NEMA Rating:
- No Enclosure
- HP @ 3 Phase - 480V:
- 3 hp
- Aux. Contact Configuration:
- 1NC
- Hz:
- 50/60
- Standards:
- BS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660
- Frame / Series / Class / Code:
- TeSys
- Auxiliary Contact Form:
- 1NC
- NEMA Size:
- Not Applicable
- Series:
- TeSys K
- Net Weight:
- 0.39 kg
- Shock Resistance:
- 10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open)
- Overvoltage Category:
- CAT III
- Inrush VA:
- 30 VA
- IP Rating:
- IP20
- Signalling Circuit Frequency:
- Less Than 400 Hz
- Rated Voltage:
- 690V AC
- Electrical Connection:
- Screw Clamp Terminals
- Features:
- Preassembled with Reversing Power Busbar
- Vibration Resistance:
- 4 G (Contactor Closed), 2 G (Contactor Open)
- Impulse Withstand Voltage:
- 8 kV
- Electrical Durability:
- 1.3 Mcycles (6 A, AC-3, Less than 440 V); 1.3 Mcycles (6 A, AC-3e, Less than 440 V)
- Environmental Attributes:
- Mercury Free, Toxic Heavy Metal Free
- Rated Making Capacity:
- 110 A
- Mounts On:
- Plate, Rail
- Max. Operating Watts:
- 1.5 kW (at 220 to 230V AC 50/60 Hz), 2.2 kW (at 380 to 415VAC 50/60 Hz), 3 kW (at 440V AC 50/60 Hz), 3 kW (at 480V AC 50/60 Hz), 3 kW (at 500 to 600V AC 50/60 Hz), 3 kW (at 660 to 690V AC 50/60 Hz)
- Fuse Amps:
- 25 A (Power Circuit), 10 A (Signalling Circuit)
- Rated Insulation Volts:
- 600/690V
- Switching Voltage:
- 17 V (Signalling Circuit)
- Watts Loss:
- 1.3W
- Fire Rating:
- UL 94 V1, NF F 16-101, NF F 16-102
- Mechanical Durability:
- 5 Mcycles
- Rated Short-Time Withstand Current:
- 90 A (at 50°C for 1 s Power Circuit), 85 A (at 50°C for 5 s Power Circuit), 80 A (at 50°C for 10 s Power Circuit), 60 A (at 50°C for 30 s Power Circuit), 45 A (at 50°C for 1 min Power Circuit), 40 A (at 50°C for 3 min Power Circuit), 80 A (For
- Operating Speed:
- 3600 cycles per hr
- Rated Breaking Capacity:
- 110 A @ 415V, 440V, 220 to 230V, 380 to 400 V; 80 A @ 500V; 70 A @ 660 to 690V
- Switching Current:
- 5 mA (Signalling Circuit)
- Tightening Torque:
- 0.8 to 1.3 Nm
- Hold VA:
- 4.5 VA
- Working Height:
- 6561.68 ft
- Impedance:
- 3 mOhm
- Operating Time:
- 10 to 20 ms (Coil Energisation and NO Closing), 10 to 20 ms (Coil De-Energisation and NO Opening)
- Thermal Amperage:
- 20 A (at 50°C Power Circuit), 10 A (at 50°C Signalling Circuit)
- Control Circuit Voltage Limits:
- Operational
- Insulation Resistance Range:
- Greater Than 10 MOhms (Signalling Circuit)
- Application:
- Motor Control
- Resistance Properties:
- Insulation Resistant
- Horsepower @ Three Phase - 600V AC:
- 3 hp
- Minimum Operating Temperature:
- -13 Degrees F
- Overall Width:
- 3.54 in
- Horsepower @ Three Phase - 240V AC:
- 1 1/2 hp
- Mechanical Operating Durability:
- 5,000,000
- Overall Height:
- 2.28 in
- Includes Auxiliary Contacts:
- Yes
- Electrical Operating Durability:
- 1,300,000
- Full Load Current - Resistive:
- 15 A
- Full Load Current - Inductive:
- 6 A
- NEMA Enclosure Rating:
- No Enclosure
- Number of Normally Open Main Contacts:
- 3
- Maximum Voltage Rating:
- 690V AC
- Overall Depth:
- 2.24 in
- Horsepower @ Single Phase - 240V AC:
- 1 1/2 hp
- Horsepower @ Single Phase - 120V AC:
- 1/2 hp
- Coil Voltage:
- 110V AC
- Maximum Operating Temperature:
- 122 Degrees F
- Reversing Capability:
- Reversing
- Horsepower @ Three Phase - 208V AC:
- 1 1/2 hp
- NEMA Enclosure Material:
- Not Applicable
- Contactor Style:
- IEC
- Mounting Style:
- DIN Rail, Plate
- Frequency:
- 50/60 Hz
- Terminal Connection Type:
- Screw Clamp Terminals
- Embedded Surge Suppressor:
- No
- Number of Auxillary Contacts:
- 1
- Horsepower @ Three Phase - 480V AC:
- 3 hp
- Connections - Terminals:
- screw clamp terminals 1 0.00 to 0.01 in² (1.5 to 4 mm²)solid; screw clamp terminals 1 0.00 to 0.01 in² (0.75 to 4 mm²)flexible without cable end; screw clamp terminals 1 0.00 to 0.00 in² (0.34 to 2.5 mm²)flexible with cable end; screw clamp ter
- Mechanical Robustness:
- Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on X axis6 Gn for 11 ms IEC
- Poles Description:
- 3P
- Device Application:
- Control
- Ambient Air Temperature For Storage:
- -58 to 176°F (-50 to 80°C)
- Associated Fuse Rating:
- 25 A gG at Less than or Equal to 440 V for power circuit; 25 A aM for power circuit; 10 A gG for signalling circuit conforming to IEC 60947; 10 A gG for signalling circuit conforming to VDE 0660
- Mounting Support:
- Plate; Rail
- Hold-In Power Consumption in VA:
- 4.5 VA (at 68°F (20°C))
- IP Degree Of Protection:
- IP20 VDE 0106
- Utilisation Category:
- AC-3; AC-3e; AC-4
- IRMS Rated Making Capacity:
- 110 A AC for power circuit conforming to IEC 60947; 110 A AC for signalling circuit conforming to IEC 60947
- Product Certifications:
- CB Scheme; CCC; UL; CSA; EAC; CE; UKCA
- Maximum Operating Rate:
- 3600 cyc/h
- Product Or Component Type:
- Reversing contactor
- Operating Altitude:
- 6561.68 ft (2000 m) without derating
- Auxiliary Contact Composition:
- 1 NC
- Motor Power KW:
- 1.5 kW 220 to 230 V AC 50/60 Hz; 2.2 kW 380 to 415 V AC 50/60 Hz; 3 kW 440/690 V AC 50/60 Hz
- Flame Retardance:
- V1 conforming to UL 94; Requirement 2 conforming to NF F 16-101; Requirement 2 conforming to NF F 16-102
- Rated Operational Voltage:
- Power circuit 690 V AC 50/60 Hz; Signalling circuit Less than or Equal to 690 V AC 50/60 Hz
- Heat Dissipation:
- 1.3 W
- Insulation Resistance:
- Greater than 10 MOhm for signalling circuit
- Non Overlap Distance:
- 0.02 in (0.5 mm)
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Ambient Air Temperature For Operation:
- -13 to 122°F (-25 to 50°C)
- Minimum Switching Voltage:
- 17 V for signalling circuit
- Rated Short Time Withstand Current:
- 90 A 122°F (50°C) - 1 s for power circuit; 85 A 122°F (50°C) - 5 s for power circuit; 80 A 122°F (50°C) - 10 s for power circuit; 60 A 122°F (50°C) - 30 s for power circuit; 45 A 122°F (50°C) - 1 min for power circuit; 40 A 122°F (50°C) -
- Control Circuit Voltage:
- 110 V AC 50/60 Hz
- Auxiliary Contacts Type:
- Instantaneous 1 NC
- Power Pole Contact Composition:
- 3 NO
- Rated Operational Current:
- 6 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 6 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
- Protective Treatment:
- TC IEC 60068; TC DIN 50016
- Average Impedance:
- 3 mOhm - Ith 20 A 50 Hz for power circuit
- Conventional Free Air Thermal Current:
- 20 A (at 140°F (60°C)) for power circuit; 10 A (at 122°F (50°C)) for signalling circuit
- Inrush Power in VA:
- 30 VA (at 68°F (20°C))
- Minimum Switching Current:
- 5 mA for signalling circuit
- Interlocking Type:
- Mechanical
- Control Circuit Type:
- AC 50/60 Hz
- Rated Insulation Voltage:
- Power circuit 600 V UL 508; Power circuit 690 V IEC 60947-4-1; Signalling circuit 690 V IEC 60947-4-1; Signalling circuit 690 V IEC 60947-5-1; Signalling circuit 600 V UL 508; Power circuit 600 V CSA C22.2 No 14; Signalling circuit 600 V CSA C22.2 No
- Package Quantity:
- 1