- Country of Origin:
- Germany
- Operator:
- Selector Switch
- NEMA Size:
- Not Applicable
- Enclosure NEMA Rating:
- No Enclosure
- Depth:
- 96 mm
- Frame Size:
- S00
- Overload Relay Amp Setting:
- 2.8 to 4A
- Amps AC:
- 2.8 to 4
- Height:
- 97 mm
- Item:
- Manual Motor Starter
- Width:
- 45 mm
- Number of Poles:
- 3
- Max. Voltage:
- 600V AC
- HP @ 3 Phase - 480V:
- 2 hp
- HP @ 1 Phase - 120V:
- 1/8 hp
- HP @ 3 Phase - 240V:
- 3/4 hp
- Pilot Light:
- No
- Standards:
- Eclass 27-37-04-01, ETIM EC000074, ETIM EC000074 IDEA 4845
- HP @ 3 Phase - 460-575V:
- 2/3
- Description/Special Features:
- Thermal-Magnetic Trip Mechanism
- HP @ 3 Phase - 575V:
- 3 hp
- Frame / Series / Class / Code:
- S00
- Phase Loss Sensitivity:
- No
- HP @ 3 Phase - 208V:
- 3/4 hp
- HP @ 1 Phase - 230V:
- 1/3 hp
- Release system:
- magnetic
- Number of auxiliary contacts as opener:
- 0
- rated service short-circuit breaking capacity Ics at 400 V, 50 Hz:
- 100000 ampere
- Rated current [In] for the power loss specification:
- 4 ampere
- Integrated auxiliary switch present:
- No
- Protection type IP:
- IP20
- Connection type:
- Screw connection
- Pole number:
- 3
- Greatest value of overload release adjustment range:
- 4 ampere
- Lowest value of setting range for overload tripper:
- 2.8 ampere
- Sensitive to phase failure:
- Yes
- min. rated operating voltage:
- 690 volt
- Rated permanent current Iu:
- 4 ampere
- Power loss per pole, current-dependent [PlIp]:
- 2.4 watt
- description of product type:
- 3RV2
- Number of auxiliary contacts as shutter:
- 0
- max. rated operating voltage:
- 690 volt
- Integrated undervoltage tripper present:
- No
- Manner of using:
- Toggle
- Rated operating power with AC-3, 230 V:
- 1 kilowatt
- Rated operating power with AC-3, 400 V:
- 2 kilowatt
- Horsepower @ Three Phase - 480V AC:
- 2 hp
- Horsepower @ Three Phase - 600V AC:
- 3 hp
- Includes Pilot Light:
- No
- Mounting Style:
- DIN Rail
- Horsepower @ Three Phase - 240V AC:
- 3/4 hp
- IP Rating:
- IP20
- Series:
- Sirius 3RV20
- Overall Depth:
- 4.35 in
- Electrical Operating Durability:
- 100,000
- Minimum Overload Relay Current Setting:
- 2.8 A
- Overall Width:
- 4.35 in
- Phase:
- Three
- Horsepower @ Single Phase - 120V AC:
- 1/8 hp
- Maximum Overload Relay Current Setting:
- 4 A
- Maximum Voltage Rating:
- 690V AC
- Overload Protection Type:
- Thermal
- NEMA Enclosure Rating:
- No Enclosure
- Overall Height:
- 4.7 in
- Horsepower @ Single Phase - 240V AC:
- 1/3 hp
- Horsepower @ Three Phase - 208V AC:
- 3/4 hp
- Terminal Connection Type:
- Screw Terminals
- Mechanical Operating Durability:
- 100,000
- Minimum Operating Temperature:
- -4 Degrees F
- Current AC:
- 4 A
- Mounting Hole Diameter:
- 1.38 in
- Starter Style:
- IEC
- Maximum Operating Temperature:
- 140 Degrees F
- Frequency:
- 50/60 Hz
- Package Quantity:
- 1