Induced Draft Blower, 115, Aluminized Steel Housing and Blower Wheel - HSJ

Tjernlund Products
SKU:
HSJ
|
UPC:
80956207043
Availability:
In Stock

Log in for pricing

(No reviews yet)
Current Stock:
Induced Draft Blower, Application Boilers, Water Heaters, For Fuel Type LP, Natural Gas, Oil, For Appliance Type Boilers, Furnaces, Unit Heaters, Water Heaters, Maximum Vent Pipe Diameter 4 in, Maximum Heater BTU Input for Gas Appliance 125,000 BtuH, Maximum Heater BTU Input for Oil Appliance 75,000 BtuH, Inlet Diameter 4 in, Outlet Diameter 4 in, Nameplate Voltage 115V AC, Current 1.26 A, Maximum Motor Speed 3,000 RPM, Maximum Static Pressure 1 3/8 in wc, Airflow @ 0.000 in SP 110 cfm
Country of Origin:
United States
Inlet and Outlet Dia. (In.):
4
Item:
Induced Draft Blower
Type:
High Temperature
Voltage:
115
Depth (In.):
7 in
Construction Material:
Aluminized Steel Housing and Blower Wheel
Amps:
1.26
Includes:
Fan Proving Switch, UC1 Universal Control
Remarks:
View Catalog Page for Selection Criteria
Height (In.):
7 7/8 in
Agency Compliance:
ETL Listed to UL378 and CAN3-B255-M81
Width (In.):
10 1/4 in
Application:
Boilers, Water Heaters
Watts:
95 W
CFM @ 0.700-In. SP:
72 10 - -
CFM @ 1.40-In. SP:
- - - -
Duct Temp. Deg. (F):
70,300,400,500
Max. Pipe Length 400:
100
Max. Pipe Length 300:
100
SP @ 530 Deg. (F):
Not Applicable
CFM @ 0.500-In. SP:
85 68 57 40
CFM @ 1.000-In. SP:
10 - - -
SP @ 390 Deg. (F):
Not Applicable
CFM @ 0.000-In. SP:
110 110 110 110
Heater Btu Input @ 390 (F):
Not Applicable
SP @ 270 Deg. (F):
Not Applicable
Max. Pipe Length 500:
100
Heater Btu Input @ 270 (F):
Not Applicable
Heater Btu Input @ 530 (F):
Not Applicable
BtuH Input:
25-100
For Use With:
Power Venter
Standards:
cETL Listed
Overall Height:
9 5/8 in
Overall Width:
9 7/8 in
Maximum Heater BTU Input for Gas Appliance:
125,000 BtuH
Blower Type:
Sidewall Power Venter
Maximum Motor Speed:
3,000 RPM
Outlet Width:
Not Applicable
Housing Material:
Steel
For Appliance Type:
Boilers, Furnaces, Unit Heaters, Water Heaters
Outlet Height:
Not Applicable
Current:
1.26 A
Nameplate Voltage:
115V AC
For Fuel Type:
LP, Natural Gas, Oil
For Maximum Pipe Length:
100 ft
Maximum Heat Input:
100 MBtuH
Inlet Diameter:
4 in
Housing Material Finish:
Aluminum Plated
Overall Depth:
7 5/8 in
Airflow @ 0.000 in SP:
110 cfm
Outlet Shape:
Round
Market:
Commercial, Residential
Includes Motor:
Yes
Airflow at Temperature:
10 cfm @ 70 Degrees F, 110 cfm @ 70 Degrees F, 67 cfm @ 70 Degrees F, 85 cfm @ 70 Degrees F
Maximum Vent Pipe Diameter:
4 in
Maximum Heater BTU Input for Oil Appliance:
75,000 BtuH
Outlet Diameter:
4 in
Power Consumption:
95 W
Maximum Static Pressure:
1 3/8 in wc
Package Quantity:
1