- Country of Origin:
- France
- Item:
- IEC Timer Module
- Delay Type:
- On Delay
- Range of Time Delay:
- 0.10 sec to 3.00 sec
- Number of Contacts:
- 2
- Contacts Normally Closed:
- 1
- Contacts Normally Open:
- 1
- Mounting:
- Front
- Max. Contact Blocks (No.):
- 1
- Starter Mounting Location:
- Front
- Number of Normally Closed Contacts:
- 1
- Maximum Voltage Rating:
- 690V AC
- Time Delay - Maximum:
- 3 sec
- IP Rating:
- IP20
- Compatible with Series:
- TeSys Deca
- Terminal Connection Type:
- Screw Clamp Terminals
- Compatible with Manufacturer Model Number:
- LC1D09B7, LC1D09BD, LC1D09F7, LC1D09M7, LC1D09P7, LC1D12B7, LC1D12BD, LC1D12M7, LC1D12P7, LC1D18B7, LC1D18BD, LC1D18M7, LC1D18P7, LC1D25B7, LC1D25BD, LC1D25M7, LC1D25P7, LC1D32B7, LC1D32M7, LC1D40AM7
- Number of Normally Open Contacts:
- 1
- Time Delay - Minimum:
- 0.3 sec
- Maximum Operating Temperature:
- 158 Degrees F
- Minimum Operating Temperature:
- -40 Degrees F
- Permissible Short-Time Rating:
- 100 A 60°C 1 s || 120 A 60°C 500 ms || 140 A 60°C 100 ms
- Connections - Terminals:
- screw clamp terminals 1 1-2.5 mm²flexible with cable end || screw clamp terminals 1 1-2.5 mm²flexible without cable end || screw clamp terminals 2 1-2.5 mm²flexible with cable end || screw clamp terminals 2 1-2.5 mm²flexible without cable end ||
- Range Compatibility:
- TeSys D CAD || TeSys D LC1D || TeSys F LC1F || TeSys F CR1F || TeSys Deca CAD || TeSys Deca LC1D
- Time Delay Range:
- 0.3...3 s
- Auxiliary Contacts Operation:
- time delay
- Rated Insulation Voltage:
- 690 V IEC 60947-5-1; 600 V UL 60947-5-1; 600 V CSA C22.2 No 60947-5-1
- Ambient Air Temperature For Operation:
- -40-70°C
- Tightening Torque:
- 1.7 N.m flat Ø 6 mm || 1.7 N.m Philips No 2 || 1.7 N.m pozidriv No 2
- Conventional Free Air Thermal Current:
- 10 A (at 140°F (60°C))
- Mounting Location:
- front
- Pole Contact Composition:
- 1 NO + 1 NC
- Non-Overlap Time:
- 1.5 ms on de-energisation no overlap between NC and NO contact || 1.5 ms on energisation no overlap between NC and NO contact
- Width:
- 44 mm
- Operating Altitude:
- 9842.52 ft (3000 m)
- Timer Type:
- on delay
- Rated Operational Current:
- 6 A at 120 V AC-15; 1.04 A at 690 V AC-15; 0.55 A at 125 V DC-13; 0.1 A at 600 V DC-13
- Depth:
- 61 mm
- Product Certifications:
- IECEE CB Scheme || UL || CSA || CCC || EAC || UKCA
- Color:
- dark grey
- Insulation Resistance:
- > 10 MOhm
- [Ie] Rated Operational Current:
- 6 A120 V AC-15 || 1.04 A690 V AC-15 || 0.55 A125 V DC-13 || 0.1 A600 V DC-13
- [Ue] Rated Operational Voltage:
- 690 V AC 25...400 Hz
- Minimum Switching Current:
- 5 mA
- Product Or Component Type:
- time delay auxiliary contact block
- [Ith] Conventional Free Air Thermal Current:
- 10 A 60°C
- Minimum Switching Voltage:
- 17 V
- [Ui] Rated Insulation Voltage:
- 690 V IEC 60947-5-1 || 600 V UL 60947-5-1 || 600 V CSA C22.2 No 60947-5-1
- Mechanical Durability:
- 5 Mcycles
- Standards:
- UL 60947-5-1 || CSA C22.2 No 60947-5-1 || GB/T 14048.5
- Irms Rated Making Capacity:
- 140 A <= 690 V AC IEC 60947-5-1 || 250 A <= 690 V DC IEC 60947-5-1
- Rated Operational Voltage:
- 690 V AC 25 to 400 Hz
- Environmental Characteristic:
- normal environment
- Ambient Air Temperature For Storage:
- -60-80°C
- Height:
- 48 mm
- Range:
- TeSys || TeSys Deca
- Product Name:
- TeSys Deca
- Protective Treatment:
- TH IEC 60068
- Ip Degree Of Protection:
- IP20 conforming to IEC 60529
- Protection Type:
- gG fuse 10 A
- Compatible with Mfr. Model No.:
- LC1D09B7, LC1D09BD, LC1D09F7, LC1D09M7, LC1D09P7, LC1D12B7, LC1D12BD, LC1D12M7, LC1D12P7, LC1D18B7, LC1D18BD, LC1D18M7, LC1D18P7, LC1D25B7, LC1D25BD, LC1D25M7, LC1D25P7, LC1D32B7, LC1D32M7, LC1D40AM7
- For Use with Mfr Model Number:
- LC1D09B7, LC1D09BD, LC1D09F7, LC1D09M7, LC1D09P7, LC1D12B7, LC1D12BD, LC1D12M7, LC1D12P7, LC1D18B7, LC1D18BD, LC1D18M7, LC1D18P7, LC1D25B7, LC1D25BD, LC1D25M7, LC1D25P7, LC1D32B7, LC1D32M7, LC1D40AM7
- Package Quantity:
- 1