IEC Magnetic Contactor, 3 Poles, 24 V DC, 50 A, Reversing: No - LC1D50ABD

Schneider Electric
SKU:
LC1D50ABD
|
UPC:
785901562542
Availability:
In Stock

Log in for pricing

(No reviews yet)
Current Stock:
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V DC, Number of Poles 3, Full Load Current - Inductive 50 A, Full Load Current - Resistive 80 A, Reversing Capability Non-Reversing, Overall Height 4.8 in, Overall Width 2.17 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC
Country of Origin:
France
Full Load Amps-Inductive:
50 A
Item:
IEC Magnetic Contactor
Action:
Non-Reversing
Full Load Amps-Resistive:
80 A
Number of Poles:
3
Coil Volts:
24 V DC
Reversing:
No
HP @ 1 Phase - 120V:
3 hp
HP @ 1 Phase - 230V:
7-1/2
Height:
2.17 in
HP @ 1 Phase - 240V:
7 1/2 hp
HP @ 3 Phase - 208V:
15 hp
Width:
2.17 in
HP @ 3 Phase - 240V:
15 hp
HP @ 3 Phase - 575V:
40 hp
Depth:
4.61 in
HP @ 3 Phase - 480V:
40 hp
Enclosure NEMA Rating:
No Enclosure
Aux. Contact Configuration:
1NO/1NC
Hz:
50/60
Frame / Series / Class / Code:
TeSys
Standards:
BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UL 508, UL Listed
Auxiliary Contact Form:
1NO/1NC
NEMA Size:
Not Applicable
Includes:
Everlink Power Connections
Series:
TeSys Deca
Vibration Resistance:
4 G (Contactor Closed), 2 G (Contactor Open)
Application:
Motor Control, Resistive Load
Impulse Withstand Voltage:
6 kV
IP Rating:
IP20
Rated Making Capacity:
140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 900 A @ 440V (Power Circuit)
Rated Short-Time Withstand Current:
400 A (at 40°C for 10 s Power Circuit), 810 A (at 40°C for 1 s Power Circuit), 84 A (at 40°C for 10 min Power Circuit), 208 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For
Includes Protective Cover:
Yes
Mounts On:
Plate, Rail
Operating Speed:
3600 cycles per hr
Electrical Durability:
1.45 Mcycles (50 A, AC-3, Less than 440 V); 0.5 Mcycles (80 A, AC-1, Less than 440 V); 1.45 Mcycles (50 A, AC-3e, Less than 440 V)
Fuse Amps:
10 A (Signalling Circuit), 100 A (Type 1 Power Circuit), 100 A (Type 2 Power Circuit)
Mechanical Durability:
10 Mcycles
Fire Rating:
UL 94 V1
Impedance:
1.5 mOhm
Features:
Built-In Bi-Directional Peak Limiting Diode Suppressor
Max. Temperature:
850°C
Electrical Connection:
Screw Clamp Terminals
Net Weight:
0.93 kg
Shock Resistance:
10 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
Overvoltage Category:
CAT III
Switching Current:
5 mA (Signalling Circuit)
Rated Voltage:
690V AC, 300V DC
Insulation Resistance Range:
Greater Than 10 MOhms (Signalling Circuit)
Rated Breaking Capacity:
900 A @ 440V
Switching Voltage:
17 V (Signalling Circuit)
Rated Insulation Volts:
600/690V
Thermal Amperage:
10 A (at 60°C Signalling Circuit), 80 A (at 60°C Power Circuit)
Tightening Torque:
1.7 Nm (Control Circuit), 2.5 to 8 Nm (Power Circuit)
Environmental Attributes:
Mercury Free, PVC Free, Pollution Degree 3
Max. Operating Watts:
15 kW (at 220 to 230V AC 50/60 Hz AC-3), 22 kW (at 380 to 400V AC 50/60 Hz AC-3), 30 kW (at 500V AC 50/60 Hz AC-3), 33 kW (at 660 to 690V AC 50/60 Hz AC-3), 25 kW (at 415V AC 50/60 Hz AC-3), 30 kW (at 440V AC 50/60 Hz AC-3), 11 kW (at 400V AC 50/60 H
Non-Overlap Time:
1.5 ms
Working Height:
Up to 9842.52 ft
Operating Time:
42.5 to 57.5 ms (Closing), 16 to 24 ms (Opening)
Signalling Circuit Frequency:
25 to 400 Hz
Control Circuit Voltage Limits:
Drop-Out DC
Maximum Operating Temperature:
140 Degrees F
Contactor Style:
IEC
Coil Voltage:
24V DC
Overall Depth:
4.72 in
Full Load Current - Inductive:
50 A
Frequency:
50/60 Hz
Overall Width:
2.17 in
Horsepower @ Three Phase - 480V AC:
40 hp
Number of Normally Open Main Contacts:
3
Mounting Style:
DIN Rail, Plate
Number of Auxillary Contacts:
2
NEMA Enclosure Rating:
No Enclosure
Horsepower @ Three Phase - 240V AC:
15 hp
Horsepower @ Three Phase - 600V AC:
40 hp
Minimum Operating Temperature:
-40 Degrees F
Horsepower @ Single Phase - 240V AC:
7 1/2 hp
Embedded Surge Suppressor:
Yes
Resistance Properties:
Fire Resistant, Insulation Resistant
Mechanical Operating Durability:
10,000,000
Horsepower @ Three Phase - 208V AC:
15 hp
Reversing Capability:
Non-Reversing
NEMA Enclosure Material:
Not Applicable
Includes Auxiliary Contacts:
Yes
Maximum Voltage Rating:
690V AC
Electrical Operating Durability:
1,450,000, 500,000
Overall Height:
4.8 in
Horsepower @ Single Phase - 120V AC:
3 hp
Terminal Connection Type:
Screw Clamp Terminals
Phase:
Three
Full Load Current - Resistive:
80 A
Package Quantity:
1