IEC Magnetic Contactor, 3 Poles, 24 V DC, 12 A, Reversing: No - XTCE012B10TD

Eaton
SKU:
XTCE012B10TD
|
UPC:
786685353760
Availability:
In Stock

Log in for pricing

(No reviews yet)
Current Stock:
IEC Magnetic Contactor, Auxiliary Contact Form 1NO, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V DC, Number of Poles 3, Full Load Current - Inductive 12 A, Full Load Current - Resistive 22 A, Reversing Capability Non-Reversing, Overall Height 2 in, Overall Width 3 in, Terminal Connection Type Screw Terminals, Frame Size B, Mounting Style DIN Rail, Panel, Series XT, Number of Auxillary Contacts 1, Contactor Style IEC, Horsepower @ Three Phase - 240V AC 3 hp
Country of Origin:
Romania
Item:
IEC Magnetic Contactor
Full Load Amps-Inductive:
12 A
Full Load Amps-Resistive:
22 A
Action:
Non-Reversing
Type:
Full voltage non-reversing contactor
Number of Poles:
3
Coil Volts:
24 V DC
Reversing:
No
HP @ 1 Phase - 120V:
1 hp
HP @ 1 Phase - 230V:
2
Height:
1.77 in
HP @ 1 Phase - 240V:
2 hp
Width:
1.77 in
HP @ 3 Phase - 208V:
3 hp
HP @ 3 Phase - 240V:
3 hp
HP @ 3 Phase - 575V:
10 hp
Depth:
2.95 in
Enclosure NEMA Rating:
No Enclosure
HP @ 3 Phase - 480V:
10 hp
Aux. Contact Configuration:
1NO
Frame / Series / Class / Code:
Frame B
Standards:
CE, CSA, EN 60947, IEC 60947, RoHS, UL Listed
Auxiliary Contact Form:
1NO
Series:
XT
NEMA Size:
Not Applicable
Electrical Connection:
Screw Terminals
IP Rating:
IP20
Product Width:
3 in
Coil Voltage:
24V DC
Product Height:
2 in
Hp Rating - Max:
1, 2, 2/ 3, 3, 10, 10 hp (1/3PH @115,200,230/200,230,460,575 V)
Amperage Rating:
12A
Contact Configuration:
1 NO
Frame Size:
B
Certifications:
UL Listed;CSA Certified;IEC 60947;EN 60947
Product Length/Depth:
3 in
Compliances:
CE Marked
Product Name:
Eaton XT IEC contactor
Overall Depth:
3 in
Horsepower @ Three Phase - 240V AC:
3 hp
NEMA Enclosure Material:
Not Applicable
Contactor Style:
IEC
Electrical Operating Durability:
1,000,000
Response Time:
Less Than12 msec (DC Operated Opening Delay), Less Than18 msec (AC Operated Opening Delay), Less Than21 msec (AC Operated Closing Delay), Less Than31 msec (DC Operated Opening Delay)
Maximum Voltage Rating:
690V AC
Includes Auxiliary Contacts:
Yes
Full Load Current - Resistive:
22 A
Horsepower @ Single Phase - 120V AC:
1 hp
Mechanical Operating Durability:
10,000,000
Terminal Connection Type:
Screw Terminals
NEMA Enclosure Rating:
No Enclosure
Overall Height:
2 in
Full Load Current - Inductive:
12 A
Horsepower @ Three Phase - 208V AC:
3 hp
Number of Auxillary Contacts:
1
Horsepower @ Single Phase - 240V AC:
2 hp
Horsepower @ Three Phase - 480V AC:
10 hp
Embedded Surge Suppressor:
Yes
Overall Width:
3 in
Horsepower @ Three Phase - 600V AC:
10 hp
Mounting Style:
DIN Rail, Panel
Maximum Operating Temperature:
122 Degrees F
Reversing Capability:
Non-Reversing
Minimum Operating Temperature:
-13 Degrees F
Frequency:
50/60 Hz
Package Quantity:
1