- Country of Origin:
- Czechia
- Full Load Amps-Inductive:
- 50 A
- Item:
- IEC Magnetic Contactor
- Full Load Amps-Resistive:
- 80 A
- Number of Poles:
- 3
- Coil Volts:
- 110 V AC
- Height:
- 127 mm
- HP @ 1 Phase - 240V:
- 7 1/2 hp
- HP @ 3 Phase - 208V:
- 15 hp
- Width:
- 85 mm
- HP @ 3 Phase - 575V:
- 40 hp
- Depth:
- 176 mm
- HP @ 3 Phase - 240V:
- 15 hp
- HP @ 3 Phase - 480V:
- 40 hp
- Aux. Contact Configuration:
- 1NO/1NC
- Series:
- LC1D
- Standards:
- CSA C22.2 No 14, IEC 60947-4-1, IEC 60947-5-1, EN 60947-5-1, EN 60947-4-1, GL, LROS, RINA, CCC, BV, DNV, GOST, CSA, UKCA
- Application:
- Motor Control, Resistive Load
- Features:
- Built-In Bi-Directional Peak Limiting Diode Suppressor
- Max. Operating Watts:
- 25 kW (at 415V AC 50 Hz AC-3), 30 kW (at 440V AC 50 Hz AC-3), 30 kW (at 500V AC 50 Hz AC-3), 33 kW (at 660 to 690V AC 50 Hz AC-3), 15 kW (at 220 to 230V AC 50 Hz AC-3), 11 kW (at 400V AC 50 Hz AC-4), 30 kW (at 1000V AC 50 Hz AC-3), 22 kW (at 380 to 4
- Control Circuit Voltage Limits:
- Operational AC
- Shock Resistance:
- 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
- Electrical Connection:
- Screw Clamp Terminals
- Inrush VA:
- 160 VA
- Non-Overlap Time:
- 1.5 ms
- Includes Protective Cover:
- Yes
- Rated Insulation Volts:
- 600/690V
- Environmental Attributes:
- Mercury Free, PVC Free, Toxic Heavy Metal Free
- Hold VA:
- 15 VA
- Rated Breaking Capacity:
- 900 A @ 440V
- Impulse Withstand Voltage:
- 8 kV
- Operating Speed:
- 3600 cycles per hr
- Tightening Torque:
- 1.7 Nm (Control Circuit), 5 Nm (Power Circuit)
- Operating Time:
- 12 to 26 ms (Closing), 20 ms (Opening)
- Rated Making Capacity:
- 140 A (AC Control Circuit), 900 A @ 440V (Power Circuit), 250 A (DC Control Circuit)
- Thermal Amperage:
- 80 A (at 60°C Power Circuit), 10 A (at 60°C Control Circuit)
- Max. Temperature:
- 850°C
- Mounts On:
- Plate, Rail
- Switching Current:
- 5 mA (Control Circuit)
- Net Weight:
- 2.185 kg
- Insulation Resistance Range:
- Greater Than 10 Mohms (Control Circuit)
- Working Height:
- Up to 9842.52 ft
- Vibration Resistance:
- 4 G (Contactor Closed), 2 G (Contactor Open)
- Fire Rating:
- UL 94 V1
- Switching Voltage:
- 17 V (Control Circuit)
- Mechanical Durability:
- 10 Mcycles
- Rated Voltage:
- 690V AC
- Fuse Amps:
- 100 A (Type 1 and 2 Power Circuit), 10 A (Control Circuit)
- Overvoltage Category:
- CAT III
- IP Rating:
- IP2X
- Conventional Free Air Thermal Current:
- 80 A (at 140°F (60°C)) for power circuit; 10 A (at 140°F (60°C)) for control circuit
- Fire Resistance:
- 1562°F (850°C) IEC 60695-2-1
- Contactor Application:
- Resistive load; Motor control
- Control Circuit Type:
- DC standard
- Motor Power KW:
- 25 kW at 415 V AC 50 Hz (AC-3); 30 kW at 440 V AC 50 Hz (AC-3); 30 kW at 500 V AC 50 Hz (AC-3); 33 kW at 660 to 690 V AC 50 Hz (AC-3); 15 kW at 220 to 230 V AC 50 Hz (AC-3); 11 kW at 400 V AC 50 Hz (AC-4); 30 kW at 1000 V AC 50 Hz (AC-3); 22 kW at 38
- Rated Insulation Voltage:
- Control circuit 600 V UL; Power circuit 600 V CSA; Power circuit 600 V UL IEC 60947-1; Control circuit 690 V IEC 60947-1; Power circuit 690 V CSA IEC 60947-1; Control circuit 600 V CSA
- Associated Fuse Rating:
- 100 A gG at Less than or Equal to 690 V coordination type 1 for power circuit; 100 A gG at Less than or Equal to 690 V coordination type 2 for power circuit conforming to IEC 60947-5-1; 10 A gG for control circuit conforming to IEC 60947-5-1
- Product Certifications:
- GL; LROS (Lloyds register of shipping); RINA; CCC; BV; DNV; GOST; CSA; UKCA; GL
- Rated Operational Voltage:
- Power circuit Less than or Equal to 690 V AC 25 to 400 Hz
- Pole Contact Composition:
- 3 NO
- Inrush Power in W:
- 19 W 68°F (20°C))
- Hold-In Power Consumption in VA:
- 15 VA 50 Hz cos phi 0.3 (at 68°F (20°C))
- Auxiliary Contacts Type:
- Mirror contact 1 NC IEC 60947-4-1; Mechanically linked 1 NO + 1 NC IEC 60947-5-1
- Hold-In Power Consumption in W:
- 7.4 W 68°F (20°C)
- Flame Retardance:
- V1 conforming to UL 94
- Poles Description:
- 3P
- Insulation Resistance:
- Greater than 10 MOhm for control circuit
- Time Constant:
- 34 ms
- Rated Operational Current:
- 80 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 50 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit; 50 A (at Less than 140°F (60°C)) at Less than or Equal to 440
- IP Degree Of Protection:
- IP2X VDE 0106; IP2X IEC 60529
- Utilisation Category:
- AC-1; AC-4; AC-3; AC-3e; AC-1
- Power Dissipation Per Pole:
- 9.6 W AC-1; 3.7 W AC-3e; 3.7 W AC-3
- Maximum Horse Power Rating:
- 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors; 15 hp at 200/208 V AC 60 Hz for 3 phase motors; 15 hp at 230/240 V AC 60 Hz for 3 phase motors; 40 hp at 460/480 V AC 60 Hz for 3 phase motors; 40 hp at 575/600 V AC 60 Hz for 3 phase motors; 3 hp at 1
- Connections - Terminals:
- Control circuit
- Maximum Operating Rate:
- 3600 cyc/h 140°F (60°C)
- Mounting Support:
- Rail; Rail
- Minimum Switching Current:
- 5 mA for control circuit
- Inrush Power in VA:
- 160 VA cos phi 0.75 (at 68°F (20°C))
- Safety Reliability Level:
- B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1; B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
- IRMS Rated Making Capacity:
- 140 A AC for control circuit conforming to IEC 60947-5-1; 900 A at 440 V for power circuit conforming to IEC 60947; 250 A DC for control circuit conforming to IEC 60947-5-1
- Mechanical Robustness:
- Shocks contactor closed 15 Gn for 11 ms); Vibrations contactor opened 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor opened 10 Gn for 11 ms)
- Control Circuit Voltage:
- 110 V DC
- Protective Cover:
- With
- Minimum Switching Voltage:
- 17 V for control circuit
- Coil Technology:
- Built-in bidirectional peak limiting diode suppressor
- Operating Altitude:
- 0 to 9842.52 ft (0 to 3000 m)
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Climatic Withstand:
- IACS E10 exposure to damp heat
- Rated Impulse Withstand Voltage:
- 8 kV IEC 60947
- Product Or Component Type:
- Contactor
- Package Quantity:
- 1