IEC Magnetic Contactor, 3 Poles, 110 V AC, 150 A - LC1D150F7

Schneider Electric
SKU:
LC1D150F7
|
UPC:
785901214489
Availability:
In Stock

Log in for pricing

(No reviews yet)
Current Stock:
IEC Magnetic Contactor
Country of Origin:
Czechia
Item:
IEC Magnetic Contactor
Full Load Amps-Inductive:
150 A
Full Load Amps-Resistive:
200 A
Number of Poles:
3
Coil Volts:
110 V AC
Height:
158 mm
HP @ 3 Phase - 208V:
40 hp
Width:
120 mm
HP @ 3 Phase - 575V:
125 hp
HP @ 3 Phase - 240V:
50 hp
Depth:
136 mm
HP @ 3 Phase - 480V:
100 hp
Aux. Contact Configuration:
1NO/1NC
Standards:
CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, CCC, GOST, DNV, UL, LROS, BV, GL, RINA, CSA, UKCA, CE, THIEC 60068-2-30
Series:
LC1D
Rated Breaking Capacity:
1400 A @ 440V
Environmental Attributes:
Mercury Free, PVC Free, Pollution Degree 3
Vibration Resistance:
4 G (Contactor Closed), 2 G (Contactor Open)
Operating Time:
20 to 35 ms (Closing), 40 to 75 ms (Opening)
Features:
Built-In Bi-Directional Peak Limiting Diode Suppressor
Max. Operating Watts:
40 kW (at 220 to 230V AC 50/60 Hz AC-3), 75 kW (at 380 to 400V AC 50/60 Hz AC-3), 80 kW 415 to (at 440V AC 50/60 Hz AC-3), 90 kW (at 500V AC 50/60 Hz AC-3), 100 kW (at 660 to 690V AC 50/60 Hz AC-3), 75 kW (at 1000V AC 50/60 Hz AC-3), 22 kW (at 400V A
Electrical Connection:
Screw Clamp Terminals
Includes Protective Cover:
Yes
Hold VA:
2 to 18 VA
Fuse Amps:
10 A (Signalling Circuit), 315 A (Type 1 Power Circuit), 250 A (Type 2 Power Circuit)
Overvoltage Category:
CAT III
Fire Rating:
UL 94 V1
Operating Speed:
1200 cycles per hr
Watts Loss:
3 to 4.5W
Max. Temperature:
850°C
Working Height:
Up to 9842.52 ft
Insulation Resistance Range:
Greater Than 10 MOhms (Signalling Circuit)
Application:
Motor Control, Resistive Load
Inrush VA:
280 to 350 VA
IP Rating:
IP20
Electrical Durability:
0.85 Mcycles (150 A, AC-3, Less than 440 V); 1 Mcycles (200 A, AC-1, Less than 440 V); 0.85 Mcycles (150 A, AC-3e, Less than 440 V)
Signalling Circuit Frequency:
25 to 400 Hz
Switching Voltage:
17 V (Signalling Circuit)
Mechanical Durability:
8 Mcycles
Tightening Torque:
1.2 Nm (Control Circuit), 12 Nm (Power Circuit)
Impedance:
0.6 mOhm
Rated Insulation Volts:
600/1000V (Power Circuit), 600/690V (Signalling Circuit)
Rated Voltage:
1000V AC, 300V DC
Impulse Withstand Voltage:
8 kV
Rated Making Capacity:
140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 1660 A @ 440V (Power Circuit)
Non-Overlap Time:
1.5 ms
Thermal Amperage:
200 A (at 60°C Power Circuit)
Switching Current:
5 mA (Signalling Circuit)
Net Weight:
2.5 kg
Mounts On:
Plate, Rail
Shock Resistance:
15 G for 11 ms (Contactor Closed), 6 G for 11 ms (Contactor Open)
Control Circuit Voltage Limits:
Drop-Out AC
Rated Short-Time Withstand Current:
250 A (at 40°C for 10 min Power Circuit), 580 A (at 40°C for 1 min Power Circuit), 1200 A (at 40°C for 10 s Power Circuit), 1400 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (
Control Circuit Type:
AC 50/60 Hz standard
Rated Insulation Voltage:
Power circuit 600 V CSA; Power circuit 600 V UL; Power circuit 1000 V IEC 60947-4-1; Signalling circuit 690 V IEC 60947-1; Signalling circuit 600 V CSA; Signalling circuit 600 V UL
Control Circuit Voltage:
110 V AC 50/60 Hz
Maximum Horse Power Rating:
40 hp at 200/208 V AC 50/60 Hz for 3 phase motors; 50 hp at 230/240 V AC 50/60 Hz for 3 phase motors; 100 hp at 460/480 V AC 50/60 Hz for 3 phase motors; 125 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Hold-In Power Consumption in VA:
2 to 18 VA 60 Hz cos phi 0.9 (at 68°F (20°C)); 2 to 18 VA 50 Hz cos phi 0.9 (at 68°F (20°C))
Permissible Ambient Air Temperature Around The Device:
-40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating
Rated Operational Voltage:
Power circuit Less than or Equal to 1000 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC
Product Or Component Type:
Contactor
Mounting Support:
Plate; Rail
Protective Cover:
With
Maximum Operating Rate:
1200 cyc/h 140°F (60°C)
Associated Fuse Rating:
10 A gG for signalling circuit conforming to IEC 60947-5-1; 315 A gG at Less than or Equal to 690 V coordination type 1 for power circuit; 250 A gG at Less than or Equal to 690 V coordination type 2 for power circuit
Climatic Withstand:
IACS E10 exposure to damp heat
Contact Compatibility:
M13
Operating Altitude:
0 to 9842.52 ft (0 to 3000 m)
Minimum Switching Voltage:
17 V for signalling circuit
Flame Retardance:
V1 conforming to UL 94
Rated Impulse Withstand Voltage:
8 kV IEC 60947
Pole Contact Composition:
3 NO
Auxiliary Contacts Type:
Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1
Heat Dissipation:
3 to 4.5 W at 50/60 Hz
Mechanical Robustness:
Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor closed 15 Gn for 11 ms); Shocks contactor open 6 Gn for 11 ms)
Average Impedance:
0.6 mOhm - Ith 200 A 50 Hz for power circuit
Product Certifications:
CCC; GOST; DNV; UL; LROS (Lloyds register of shipping); BV; GL; RINA; CSA; UKCA; CE
IRMS Rated Making Capacity:
140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 1660 A at 440 V for power circuit conforming to IEC 60947
Pollution Degree:
3
Insulation Resistance:
Greater than 10 MOhm for signalling circuit
Coil Technology:
Built-in bidirectional peak limiting diode suppressor
Rated Operational Current:
200 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 150 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 150 A (at Less than 140°F (60°C)) at Less than or Equal to 4
IP Degree Of Protection:
IP20 front face IEC 60529
Poles Description:
3P
Utilisation Category:
AC-4; AC-3; AC-1; AC-3e
Fire Resistance:
1562°F (850°C) IEC 60695-2-1
Rated Short Time Withstand Current:
250 A 104°F (40°C) - 10 min for power circuit; 580 A 104°F (40°C) - 1 min for power circuit; 1200 A 104°F (40°C) - 10 s for power circuit; 1400 A 104°F (40°C) - 1 s for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for sig
Auxiliary Contact Composition:
1 NO + 1 NC
Motor Power KW:
40 kW at 220 to 230 V AC 50/60 Hz (AC-3); 75 kW at 380 to 400 V AC 50/60 Hz (AC-3); 80 kW at 415 to 440 V AC 50/60 Hz (AC-3); 90 kW at 500 V AC 50/60 Hz (AC-3); 100 kW at 660 to 690 V AC 50/60 Hz (AC-3); 75 kW at 1000 V AC 50/60 Hz (AC-3); 22 kW at 4
Conventional Free Air Thermal Current:
200 A (at 140°F (60°C)) for power circuit
Inrush Power in VA:
280 to 350 VA 60 Hz cos phi 0.9 (at 68°F (20°C)); 280 to 350 VA 50 Hz cos phi 0.9 (at 68°F (20°C))
Contactor Application:
Motor control; Resistive load
Safety Reliability Level:
B10d = 684932 cycles contactor with nominal load EN/ISO 13849-1; B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1
Minimum Switching Current:
5 mA for signalling circuit
Connections - Terminals:
Control circuit
Protective Treatment:
THIEC 60068-2-30
Power Dissipation Per Pole:
24 W AC-1; 13.5 W AC-3; 13.5 W AC-3e
Package Quantity:
1