Cable Pull Switch, 10A, Left, 1NO+1NC - XY2CE4A010H7

Telemecanique Sensors
SKU:
XY2CE4A010H7
|
UPC:
785901952879
Availability:
In Stock

Log in for pricing

(No reviews yet)
Current Stock:
Emergency Cable Pull Switch, Switch Function Momentary, Mounting Style Single End, AC Contact Rating 3 A @ 240 V, Contact Form 1NO/1NC, Max. Cable Span 165 ft, Operating Force Not Applicable, NEMA Rating 1, 12, 4, Indicator No Indicator, Cable Connection Location Left, Thermal Amperage 10 A, Length 9.0 in, Width 9.02 in, Depth 4.13 in, Switching Ability Single Cable, DC Contact Rating 0.27 A @ 250 V, Min. Current Not Applicable, Case Material Zamak, Wiring Entry 1/2 in NPT, IP Rating IP65
Country of Origin:
Multiple
Item:
Emergency Cable Pull Switch
Switch Function:
Momentary
Mounting Style:
Single End
AC Contact Rating:
3 A @ 240 V
Contact Form:
1NO/1NC
Reset:
Push Button
Max. Cable Span:
165 ft
Operating Force:
Not Applicable
NEMA Rating:
1, 12, 4
Indicator:
No Indicator
Switching Ability:
Single Cable
DC Contact Rating:
0.27 A @ 250 V
Min. Current:
Not Applicable
Length:
9.0 in
IP Rating:
IP65
For Use With:
Preventa XPS Safety Relays
Standards:
CCC, CSA, CSA C22.2 No. 14 Machinery Directive 2006/42/EC, EN/IEC 60204-1, EN/IEC 60947-5, EN/IEC 60947-5-5, EN/ISO 13850, UL 508, Work Equipment Directive 2009/104/EC
Cable Connection Location:
Left
Wiring Entry:
1/2 in NPT
Case Material:
Zamak
Thermal Amperage:
10 A
Depth:
4.13 in
Width:
9.02 in
Length (Straight Wireway):
9.0 in
Series:
XY2CH
Body Material:
zamak
Product Or Component Type:
latching emergency stop rope pull switch
Number Of Cables:
1
Connections - Terminals:
screw clamp terminal, 1 x 0.5 to 2 x 1.5 mm²
Shock Resistance:
50 gn 11 ms EN/IEC 60068-2-27
Protective Treatment:
TC
Product Certifications:
CSA
Tightening Torque:
0.8-1.2 N.m
Compatibility Code:
XY2CE
Device Short Name:
XY2CE
Distance Between Cable Supports:
5-5 m
Trigger Cable Anchor Point:
LH side
Mechanical Durability:
60000 cycles
[Uimp] Rated Impulse Withstand Voltage:
6 kV EN/IEC 60947-1
[Ithe] Conventional Enclosed Thermal Current:
10 A
Maximum Resistance Across Terminals:
25 MOhm EN/IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A
Contacts Type And Composition:
1 NC + 1 NO
Local Signalling:
without pilot light
Ambient Air Temperature For Storage:
-40-70°C
Positive Opening:
with EN/IEC 60947-5-1
Contact Operation:
snap action
Overvoltage Category:
class I EN/IEC 61140 || class I NF C 20-030
Vibration Resistance:
10 gn 10-300 Hz)EN/IEC 60068-2-6
Marking:
CE
Cover Material:
stainless steel
Ip Degree Of Protection:
IP66 IEC 60529
Housing Colour:
blue
Cable Entry Number:
3 tapped entry Pg 13.5 cable gland
Ambient Air Temperature For Operation:
-25-70°C
[Ie] Rated Operational Current:
3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A
Trigger Cable Maximum Length:
50 m
[Ui] Rated Insulation Voltage:
500 V 3)EN/IEC 60947-1 || 300 VUL 508 || 300 VCSA C22.2 No 14
Short-Circuit Protection:
10 A cartridge fuse gG EN/IEC 60269
Operating Temperature - Minimum:
-13 Degrees F
Cable Span - Maximum:
164 ft
Action:
Momentary
Overall Depth:
4.13 in
Manufacturer Warranty Length:
18 mo
Overall Width:
9.02 in
Operating Temperature - Maximum:
158 Degrees F
NEMA Enclosure Rating:
1, 12, 4
Thermal Current:
10 A
Package Quantity:
1