Cable Pull Switch, 10A, Left, 1NO+1NC - XY2CE2A250H7

Telemecanique Sensors
SKU:
XY2CE2A250H7
|
UPC:
785901459590
Availability:
In Stock

Log in for pricing

(No reviews yet)
Current Stock:
Emergency Cable Pull Switch, Switch Function Maintained, Mounting Style Single End, AC Contact Rating 3 A @ 240 V, Contact Form 1NO/1NC, Booted Push Button Reset, Max. Cable Span 165 ft, Operating Force Not Applicable, NEMA Rating 1, 12, 4, Indicator No Indicator, Cable Connection Location Left, Thermal Amperage 10 A, Length 9.0 in, Width 9.02 in, Depth 4.13 in, Switching Ability Single Cable, DC Contact Rating 0.27 A @ 250 V, Min. Current Not Applicable, Case Material Zamak
Country of Origin:
Multiple
Item:
Emergency Cable Pull Switch
Switch Function:
Maintained
Mounting Style:
Single End
AC Contact Rating:
3 A @ 240 V
Contact Form:
1NO/1NC
Reset:
Booted Push Button
Max. Cable Span:
165 ft
Operating Force:
Not Applicable
NEMA Rating:
1, 12, 4
Indicator:
No Indicator
Switching Ability:
Single Cable
DC Contact Rating:
0.27 A @ 250 V
IP Rating:
IP65
Standards:
CCC, CSA, CSA C22.2 No. 14 Machinery Directive 2006/42/EC, EN/IEC 60204-1, EN/IEC 60947-5, EN/IEC 60947-5-5, EN/ISO 13850, UL 508, Work Equipment Directive 2009/104/EC
Width:
9.02 in
For Use With:
Preventa XPS Safety Relays
Length:
9.0 in
Thermal Amperage:
10 A
Depth:
4.13 in
Min. Current:
Not Applicable
Wiring Entry:
1/2 in NPT
Case Material:
Zamak
Cable Connection Location:
Left
Length (Straight Wireway):
9.0 in
Body Material:
zamak
Series:
XY2CE
Cover Material:
stainless steel
Ambient Air Temperature For Storage:
-40-70°C
Positive Opening:
with EN/IEC 60947-5-1
Product Certifications:
UL category NISD emergency stop devices || CSA || CCC
Overvoltage Category:
class I EN/IEC 61140 || class I NF C 20-030
Vibration Resistance:
10 gn 10-300 Hz)EN/IEC 60068-2-6
Tightening Torque:
0.8-1.2 N.m
[Ithe] Conventional Enclosed Thermal Current:
10 A
[Ui] Rated Insulation Voltage:
500 V 3)EN/IEC 60947-1 || 300 VUL 508 || 300 VCSA C22.2 No 14
Product Or Component Type:
latching emergency stop rope pull switch
Number Of Cables:
1
Distance Between Cable Supports:
5-5 m
Cable Entry Number:
3 tapped entry 1/2 NPT conduit entry"
Housing Colour:
red RAL 3000
Device Short Name:
XY2CE
Safety Level:
can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and
Shock Resistance:
50 gn 11 ms EN/IEC 60068-2-27
Contact Operation:
slow-break
Compatibility Code:
XY2CE
Mechanical Durability:
60000 cycles
Maximum Resistance Across Terminals:
25 MOhm EN/IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A
Local Signalling:
without pilot light
Ambient Air Temperature For Operation:
-25-70°C
Trigger Cable Maximum Length:
70 m
Protective Treatment:
TC
Connections - Terminals:
screw clamp terminal, 1 x 0.5 to 2 x 1.5 mm²
Ip Degree Of Protection:
IP66 IEC 60529
Contacts Type And Composition:
1 NC + 1 NO
Short-Circuit Protection:
10 A cartridge fuse gG EN/IEC 60269
[Uimp] Rated Impulse Withstand Voltage:
6 kV EN/IEC 60947-1
[Ie] Rated Operational Current:
3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A
Trigger Cable Anchor Point:
LH side
Terminals Description Iso N°1:
(13-14)NO || (21-22)NC
Marking:
CE
Operating Temperature - Maximum:
158 Degrees F
Cable Span - Maximum:
164 ft
NEMA Enclosure Rating:
1, 12, 4
Overall Width:
9.02 in
Action:
Maintained
Overall Depth:
4.13 in
Manufacturer Warranty Length:
18 mo
Operating Temperature - Minimum:
-13 Degrees F
Thermal Current:
10 A
Package Quantity: