- Country of Origin:
- France
- Item:
- 12A Selfprrevstr W/Terms Luc*Bl
- Coil Volts:
- 24V DC
- Auxiliary Contact Form:
- Linked contacts (1 NO + 1 NC) IEC 60947-4-1; Mirror contact (1 NC) IEC 60947-1
- Starter Type:
- Reversing
- Number of Poles:
- 3
- Standards:
- EN 60947-6-2; IEC 60947-6-2; UL 60947-4-1, with phase barrier; CSA C22.2 No 60947-4-1, with phase barrier; CE; CCC; EAC; ASEFA; ATEX; Marine
- Width:
- 45 mm
- Features:
- Mercury Free; Resistance to Fire, Electrostatic Discharge, Fast Transients, Radiated Fields, Shock & Vibration; Suitability For Isolation
- Hz:
- 40 to 60 Hz
- Height:
- 224 mm
- Depth:
- 126 mm
- Weight:
- 1.27 kg
- Operating Voltage:
- 690V AC
- Tightening Torque:
- Control circuit 7.08 to 10.62 lbf.in (0.8 to 1.2 N.m) flat 0.20 in (5 mm); Control circuit 7.08 to 10.62 lbf.in (0.8 to 1.2 N.m) Philips no 1 0.20 in (5 mm); Power circuit 16.82 to 22.13 lbf.in (1.9 to 2.5 N.m) flat 0.24 in (6 mm); Power circuit 16.8
- Inrush Restraint Duration:
- 15 ms DC
- Immunity To Microbreaks:
- 3 ms control circuit
- Heat Dissipation:
- 2 W control circuit with LUCA, LUCB, LUCC, LUCD; 1.7 W control circuit with LUCM
- Product Or Component Type:
- Reversing power base
- IP Degree Of Protection:
- IP20 IEC 60947-1 front panel and wired terminals); IP20 IEC 60947-1 other faces); IP40 IEC 60947-1 front panel outside connection zone)
- Typical Current Consumption:
- 120 mA 24 V DC I maximum while closing; 120 mA 24 V DC I rms sealed
- Rated Operational Current:
- 12 A Less than or Equal to 440 V; 12 A 500 V; 9 A 690 V
- Resistance To Electrostatic Discharge:
- 8 kV 3 in open air IEC 61000-4-2; 8 kV 4 on contact IEC 61000-4-2
- Device Application:
- Motor control; Motor protection
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Protective Treatment:
- TH IEC 60068
- Mechanical Durability:
- 15 Mcycles
- Product Name:
- TeSys Ultra
- Control Circuit Voltage:
- 24 V DC
- Shock Resistance:
- 10 gn power poles open IEC 60068-2-27; 15 gn power poles closed IEC 60068-2-27
- Resistance To Fast Transients:
- 2 kV 3 serial link IEC 61000-4-4; 4 kV 4 all circuits except for serial link IEC 61000-4-4
- Auxiliary Contacts Type:
- Linked contacts 1 NO + 1 NC) IEC 60947-4-1; Mirror contact 1 NC) IEC 60947-1
- Conventional Free Air Thermal Current:
- 12 A
- Utilisation Category:
- AC-43; AC-44; AC-41
- Maximum Operating Rate:
- 3600 cyc/h
- Fire Resistance:
- 1760°F (960°C) parts supporting live components IEC 60695-2-12; 1202°F (650°C) IEC 60695-2-12
- Operating Time:
- 150 ms with change of direction power circuit; 75 ms without change of direction power circuit; 35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM control circuit; 75 ms closing with LUCM control circuit; 70 ms closing with LUCA, LUCB, LUCC, LUCD contro
- Ambient Air Temperature For Storage:
- -40 to 185°F (-40 to 85°C)
- Rated Operational Voltage:
- 690 V AC power circuit
- Vibration Resistance:
- 2 gn 5 to 300 Hz) power poles open IEC 60068-2-27; 4 gn 5 to 300 Hz) power poles closed IEC 60068-2-27
- Connections - Terminals:
- Control circuit screw clamp terminals 1 0.00 to 0.00 in² (0.34 to 1.5 mm²) flexible with cable end; Control circuit screw clamp terminals 1 0.00 to 0.00 in² (0.75 to 1.5 mm²) flexible without cable end; Control circuit screw clamp terminals 1 0.0
- Product Compatibility:
- Control unit LUC.X6BL; Control unit LUC.1XBL; Control unit LUC.05BL; Control unit LUC.12BL
- Fixing Mode:
- Clipped DIN rail; Screw-fixed plate)
- Rated Insulation Voltage:
- 690 V IEC 60947-6-2 3; 600 V UL 60947-4-1; 600 V CSA C22.2 No 60947-4-1
- Safe Separation Of Circuit:
- 400 V SELV between the control and auxiliary circuits IEC 60947-1 appendix N; 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 appendix N
- Poles Description:
- 3P
- Ambient Air Temperature For Operation:
- -13 to 140°F (-25 to 60°C) with LUCM; -13 to 158°F (-25 to 70°C) with LUCA, LUCB, LUCC, LUCD
- Compatibility Code:
- LU2B
- Operating Altitude:
- 6561.68 ft (2000 m)
- Resistance To Radiated Fields:
- 9.14 V/m (10 V/m) 3 IEC 61000-4-3
- Product Certifications:
- CE; UL; CSA; CCC; EAC; ASEFA; ATEX; Marine
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Immunity To Voltage Dips:
- 70% / 500 ms IEC 61000-4-11
- Rated Service Breaking Capacity:
- 50 kA 230 V; 50 kA 440 V; 10 kA 500 V; 4 kA 690 V
- Suitability For Isolation:
- Yes
- Rated Impulse Withstand Voltage:
- 6 kVIEC 60947-6-2
- Immunity To Radioelectric Fields:
- 10 V IEC 61000-4-6
- Control Circuit Voltage Limits:
- 14.5 V DC drop-out; 20 to 27 V DC in operation
- Package Quantity:
- 1