- Country of Origin:
- United States
- Pipe Size - Valves:
- 3/4 in
- Electrical Connections:
- 1/2 Conduit"
- Valve Design:
- 2-Way/2-Position
- Voltage:
- 120V AC
- Item:
- Solenoid Valve
- Orifice Dia.:
- 3/64 in
- Valve Configuration:
- Normally Closed
- Body Material - Valves:
- CPVC
- Body Material:
- CPVC
- Overall Width:
- 3 in
- Max. Operating Pressure Differential Light Oil:
- 120 psi
- Safe Working Water Pressure:
- 120 psi
- Pipe Size:
- 3/4";NEMA Rating=4"
- Min. Operating Pressure Differential:
- 0 psi
- Max. Operating Pressure Differential Water:
- 120 psi
- Coil Insulation Class:
- B
- Seal Material:
- EPDM
- Overall Height:
- 6 5/8 in
- Valve Ways and Positions:
- 2-Way/2-Position
- Operation:
- Direct Acting
- Seal Material - Valves:
- EPDM
- Environmental Rating - Valves:
- Corrosive, Indoor, Outdoor
- Max. Flow Rate:
- 5 fps
- Coil Enclosure:
- Watertight
- Max. Fluid Temp.:
- 190 Degrees F
- Coefficient of Volume:
- 3.2
- Overall Length:
- 5 5/16 in
- Hz:
- 50 to 60
- Operation Type:
- Direct Acting
- Standards:
- CSA, UL Listed
- Operating Pressure Differential Water - Minimum:
- Not Applicable
- Orifice Diameter:
- 3/8 in
- Operating Pressure Differential Steam - Maximum:
- Not Rated
- Inlet Connection Type:
- NPT
- Operating Pressure Differential Water - Maximum:
- 90 psi
- Fluid Temperature - Maximum:
- 200 Degrees F
- Operating Pressure Differential Cryogenic Fluid - Maximum:
- Not Applicable
- Nominal Pipe Size:
- 3/4 in
- Operating Pressure Differential - Minimum:
- 0 psi
- Valve Ways:
- 2-Way
- Valve Positions:
- 2-Position
- Operating Pressure Differential Natural Gas - Minimum:
- Not Applicable
- Operating Pressure Differential Liquid CO2 - Maximum:
- Not Applicable
- Operating Pressure Differential Hot Water - Minimum:
- Not Applicable
- Operating Pressure Differential Natural Gas - Maximum:
- Not Applicable
- Operating Pressure Differential Fuel Gas - Maximum:
- Not Applicable
- Ambient Temperature - Minimum:
- 34 Degrees F
- Valve Type:
- Inline Single
- Airflow - Maximum:
- 7 gpm
- Operating Pressure Differential Fuel Gas - Minimum:
- Not Applicable
- Operating Pressure Differential Steam - Minimum:
- Not Applicable
- Operating Pressure Differential Light Oil - Minimum:
- Not Applicable
- Valve Starting Configuration:
- Normally Closed
- Valve Body Style:
- Straight
- Thread Type:
- NPT
- Operating Pressure Differential Fuel Oil - Maximum:
- Not Applicable
- For Media:
- Acids, Salt Water, Water
- Operating Pressure Differential - Maximum:
- 90 psi
- Operating Pressure Differential Air/Inert Gas - Minimum:
- Not Applicable
- Outlet Connection Type:
- NPT
- NEMA Enclosure Rating:
- 4
- Includes Seal:
- Yes
- Operating Pressure Differential Fuel Oil - Minimum:
- Not Applicable
- Includes Coil:
- Yes
- Operating Pressure Differential Cryogenic Fluid - Minimum:
- Not Applicable
- Fluid Temperature - Minimum:
- 120 Degrees F
- Ambient Temperature - Maximum:
- 190 Degrees F
- Operating Pressure Differential Hot Water - Maximum:
- Not Rated
- Mounting Orientation:
- Horizontal or Vertical
- Operating Pressure Differential Light Oil - Maximum:
- 120 psi
- Environmental Rating:
- Corrosive, Indoor, Outdoor
- Wattage:
- 19.2 W
- Operating Pressure Differential Air/Inert Gas - Maximum:
- Not Rated
- Coefficient of Volume (Cv):
- 3.2
- Frequency:
- 60 Hz
- Operating Pressure Differential Liquid CO2 - Minimum:
- Not Applicable
- Package Quantity:
- 1