- Country of Origin:
- Mexico
- Pipe Size - Valves:
- 3/8 in
- Center Line Pipe Center Size:
- 4 in
- Electrical Connections:
- 1/2 Conduit w/18" Leads"
- Valve Design:
- 4-Way/2-Position
- Voltage:
- 120V AC
- Item:
- Solenoid Valve
- Orifice Dia.:
- 3/16 in
- Valve Configuration:
- Universal
- Body Material - Valves:
- Brass
- Seal Material - Valves:
- NBR
- Min. Operating Pressure Differential:
- 0 psi
- Pipe Size:
- 3/8";Max. Operating Pressure Differential Water=100 psi"
- Seal Material:
- NBR
- Overall Length:
- 2 15/16 in
- Max. Fluid Temp.:
- 160 Degrees F
- Max. Operating Pressure Differential Air/Inert Gas:
- 125 psi
- Watts:
- 20.1 W
- Coefficient of Volume:
- 0.7
- NEMA Rating:
- 3, 3S, 4, 4X, 6, 6P, 7, 9
- Coil Insulation Class:
- F
- Max. Operating Pressure Differential Light Oil:
- 100 psi
- Overall Height:
- 4 7/16 in
- Environmental Rating - Valves:
- Explosion Proof, Indoor, Outdoor
- Hz:
- 60
- Coil Enclosure:
- Explosionproof and Watertight
- Valve Ways and Positions:
- 4-Way/2-Position
- Overall Width:
- 2 9/16 in
- Body Material:
- Brass
- Media:
- Air/Inert Gas, Light Oil and Water
- Operation Type:
- Direct Acting
- Application:
- Analytical and Diagnostic Equipment, Biofuel and Heating Systems, Dust Collector Systems, Heating Equipment, Refining Applications
- Standards:
- CSA, UL Listed
- Center Le Pipe Center Size:
- 4""
- Operating Pressure Differential Light Oil - Maximum:
- 100 psi
- Nominal Pipe Size:
- 3/8 in
- Valve Ways:
- 4-Way
- Operating Pressure Differential Liquid CO2 - Minimum:
- Not Applicable
- Operating Pressure Differential - Minimum:
- 0 psi
- Environmental Rating:
- Indoor, Outdoor
- Operating Pressure Differential Fuel Gas - Maximum:
- Not Applicable
- Ambient Temperature - Minimum:
- 32 Degrees F
- Fluid Temperature - Maximum:
- 160 Degrees F
- Operating Pressure Differential Natural Gas - Minimum:
- Not Applicable
- Inlet Connection Type:
- NPTF
- Coefficient of Volume (Cv):
- 0.7
- Operating Pressure Differential Liquid CO2 - Maximum:
- Not Applicable
- Valve Type:
- NAMUR Mount
- Valve Positions:
- 2-Position
- For Media:
- Air, Inert Gases, Light Oil, Water
- Operating Pressure Differential Light Oil - Minimum:
- 0 psi
- Operating Pressure Differential Hot Water - Maximum:
- Not Rated
- Operating Pressure Differential Water - Minimum:
- 0 psi
- Ambient Temperature - Maximum:
- 125 Degrees F
- Operating Pressure Differential Fuel Gas - Minimum:
- Not Applicable
- Mounting Orientation:
- Horizontal or Vertical
- Wattage:
- 20.1 W
- Operating Pressure Differential Steam - Minimum:
- Not Applicable
- Orifice Diameter:
- 3/16 in
- Operating Pressure Differential Cryogenic Fluid - Minimum:
- Not Applicable
- Operating Pressure Differential Cryogenic Fluid - Maximum:
- Not Applicable
- NEMA Enclosure Rating:
- 3, 3S, 4, 4X, 6, 6P, 7, 9
- Operating Pressure Differential Steam - Maximum:
- Not Rated
- Thread Type:
- NPT
- Frequency:
- 60 Hz
- Operating Pressure Differential Natural Gas - Maximum:
- Not Applicable
- Operating Pressure Differential Air/Inert Gas - Maximum:
- 125 psi
- Operating Pressure Differential Fuel Oil - Maximum:
- Not Applicable
- Operating Pressure Differential Air/Inert Gas - Minimum:
- 0 psi
- Operating Pressure Differential Fuel Oil - Minimum:
- Not Applicable
- Operating Pressure Differential Water - Maximum:
- 100 psi
- Outlet Connection Type:
- NPTF
- Includes Coil:
- Yes
- Includes Seal:
- Yes
- Package Quantity:
- 1