120V AC Brass Solenoid Valve, Normally Closed, 1/2 in Pipe Size - 8223G003

Redhat
SKU:
8223G003
|
UPC:
94701570849
Availability:
In Stock

Log in for pricing

(No reviews yet)
Current Stock:
Solenoid Valve, Valve Ways 2-Way, Valve Starting Configuration Normally Closed, Valve Type High Pressure, Nominal Pipe Size 1/2 in, Orifice Diameter 3/8 in, Body Material Brass, Coefficient of Volume (Cv) 3.2, Operating Pressure Differential Air/Inert Gas - Maximum 1,500 psi, Operating Pressure Differential Fuel Gas - Maximum Not Applicable, Seal Material Nylon, Voltage 110V AC, 120V AC, Operating Pressure Differential Fuel Oil - Maximum Not Applicable
Country of Origin:
United States
Pipe Size - Valves:
1/2 in
Center Line Pipe Center Size:
3 1/8 in
Electrical Connections:
1/2 Conduit w/18" Leads"
Valve Design:
2-Way/2-Position
Voltage:
120V AC
Item:
Solenoid Valve
Orifice Dia.:
3/8 in
Valve Configuration:
Normally Closed
Body Material - Valves:
Brass
Coil Enclosure:
Watertight No Junction Box
NEMA Rating:
1, 2, 3, 3S, 4, 4X
Pipe Size:
1/2";Max. Operating Pressure Differential Light Oil=1,500 psi"
Max. Operating Pressure Differential Water:
1,500 psi
Environmental Rating - Valves:
Indoor, Outdoor
Overall Length:
3 1/32 in
Min. Operating Pressure Differential:
25 psi
Overall Width:
1 15/16 in
Body Material:
Brass
Hz:
50/60
Media:
Air/Inert Gas, Light Oil and Water
Coil Insulation Class:
F
Overall Height:
4 5/16 in
Coefficient of Volume:
3.2
Max. Operating Pressure Differential Air/Inert Gas:
1,500 psi
Seal Material:
NBR
Watts:
17.1 W
IP Rating:
66
Valve Ways and Positions:
2-Way/2-Position
Seal Material - Valves:
NBR
Max. Fluid Temp.:
200 Degrees F
Standards:
CSA
Application:
Car Wash Equipment
Operation Type:
Pilot Operated
Operating Pressure Differential Steam - Maximum:
Not Rated
Orifice Diameter:
3/8 in
Operating Pressure Differential Liquid CO2 - Minimum:
Not Applicable
Operating Pressure Differential Natural Gas - Minimum:
Not Applicable
Operating Pressure Differential Fuel Oil - Minimum:
Not Applicable
Operating Pressure Differential Light Oil - Minimum:
25 psi
Mounting Orientation:
Horizontal or Vertical
Operating Pressure Differential Cryogenic Fluid - Minimum:
Not Applicable
Inlet Connection Type:
NPTF
Includes Coil:
Yes
Valve Positions:
2-Position
Operating Pressure Differential Liquid CO2 - Maximum:
Not Applicable
Valve Starting Configuration:
Normally Closed
NEMA Enclosure Rating:
1, 2, 3, 3S, 4, 4X
Includes Seal:
Yes
Operating Pressure Differential Natural Gas - Maximum:
Not Applicable
Ambient Temperature - Maximum:
140 Degrees F
Operating Pressure Differential Air/Inert Gas - Maximum:
1,500 psi
Operating Pressure Differential Fuel Gas - Maximum:
Not Applicable
Operating Pressure Differential Light Oil - Maximum:
1,500 psi
Operating Pressure Differential Hot Water - Minimum:
Not Applicable
Operating Pressure Differential Cryogenic Fluid - Maximum:
Not Applicable
Valve Type:
High Pressure
Operating Pressure Differential Hot Water - Maximum:
Not Rated
Operating Pressure Differential Steam - Minimum:
Not Applicable
Operating Pressure Differential Water - Maximum:
1,500 psi
Nominal Pipe Size:
1/2 in
Operating Pressure Differential - Minimum:
25 psi
Thread Type:
NPT
Valve Ways:
2-Way
Fluid Temperature - Maximum:
200 Degrees F
Ambient Temperature - Minimum:
14 Degrees F
Frequency:
50 Hz, 60 Hz
Operating Pressure Differential Air/Inert Gas - Minimum:
25 psi
Wattage:
17.1 W
Environmental Rating:
Hazardous, Indoor, Outdoor
Coefficient of Volume (Cv):
3.2
Operating Pressure Differential Fuel Gas - Minimum:
Not Applicable
Operating Pressure Differential Water - Minimum:
25 psi
Outlet Connection Type:
NPTF
For Media:
Air, Inert Gases, Light Oil, Water
Operating Pressure Differential Fuel Oil - Maximum:
Not Applicable
Center Le Pipe Center Size:
3 1/8""
Package Quantity:
1