- Country of Origin:
- Mexico
- Pipe Size - Valves:
- 1/4 in
- Center Line Pipe Center Size:
- 2 19/32 in
- Electrical Connections:
- 1/2 Conduit"
- Valve Design:
- 2-Way/2-Position
- Voltage:
- 120V AC
- Item:
- Fuel Oil Solenoid Valve
- Orifice Dia.:
- 3/32 in
- Valve Configuration:
- Normally Closed
- Body Material - Valves:
- Brass
- Seal Material:
- FKM
- Overall Width:
- 1 11/16 in
- Max. Operating Pressure Differential Light Oil:
- 350 psi
- Max. Operating Pressure Differential Air/Inert Gas:
- 500
- Standards:
- CSA for Safety Shutoff, FM, UL
- Valve Ways and Positions:
- 2-Way/2-Position
- Max. Operating Pressure Differential Water:
- 350 psi
- Watts:
- 9.1 W
- Coil Enclosure:
- General Purpose No Junction Box and Watertight
- Application:
- For Control of Commercial and Industrial Oil Burners
- NEMA Rating:
- 1, 2, 3, 3S, 4, 4X
- Environmental Rating - Valves:
- Indoor, Outdoor
- Max. Operating Pressure Differential:
- 350 psi
- Body Material:
- Brass
- Max. Fluid Temp.:
- 210 Degrees F
- Coil Insulation Class:
- F
- Ambient Temp. Range:
- 5 Degrees to 131 Degrees F
- Hz:
- 50/60
- Min. Operating Pressure Differential:
- 0 psi
- Seal Material - Valves:
- FKM
- Overall Height:
- 2 27/32 in
- Overall Length:
- 1 9/16 in
- Pipe Size:
- 1/4";Coefficient of Volume=0.21"
- Operation Type:
- Direct Acting
- Center Le Pipe Center Size:
- 2 19/32""
- NEMA Enclosure Rating:
- 1, 2, 3, 3S, 4, 4X
- Operating Pressure Differential Hot Water - Minimum:
- Not Applicable
- Operating Pressure Differential Fuel Gas - Maximum:
- Not Applicable
- Ambient Temperature - Minimum:
- -13 Degrees F
- Operating Pressure Differential Fuel Oil - Maximum:
- 350 psi
- For Media:
- Aggressive Gases, Aggressive Liquids, Air, Ammonia, Biodiesel Fuel, Cryogenic Fluids, Fuel Oil, Hot Water, Inert Gases, Light Oil, Liquid Propane Gas, Natural Gas, Oxygen, Steam, Water
- Operating Pressure Differential Liquid CO2 - Maximum:
- Not Applicable
- Orifice Diameter:
- 3/32 in
- Wattage:
- 9.1 W
- Operating Pressure Differential Air/Inert Gas - Minimum:
- 0 psi
- Fluid Temperature - Maximum:
- 210 Degrees F
- Operating Pressure Differential Liquid CO2 - Minimum:
- Not Applicable
- Operating Pressure Differential - Maximum:
- 350 psi
- Valve Ways:
- 2-Way
- Operating Pressure Differential Natural Gas - Minimum:
- Not Applicable
- Inlet Connection Type:
- NPTF
- Operating Pressure Differential Fuel Gas - Minimum:
- Not Applicable
- Operating Pressure Differential Water - Minimum:
- Not Applicable
- Includes Seal:
- Yes
- Operating Pressure Differential Light Oil - Minimum:
- Not Applicable
- Operating Pressure Differential Hot Water - Maximum:
- Not Rated
- Nominal Pipe Size:
- 1/4 in
- Operating Pressure Differential Cryogenic Fluid - Minimum:
- Not Applicable
- Environmental Rating:
- Corrosive, Hazardous, Indoor, Outdoor
- Operating Pressure Differential Water - Maximum:
- 350 psi
- Operating Pressure Differential Steam - Maximum:
- Not Rated
- Valve Type:
- High Flow
- Includes Coil:
- Yes
- Operating Pressure Differential Light Oil - Maximum:
- 350 psi
- Thread Type:
- NPT
- Valve Positions:
- 2-Position
- Ambient Temperature - Maximum:
- 131 Degrees F
- Operating Pressure Differential Fuel Oil - Minimum:
- 0 psi
- Outlet Connection Type:
- NPTF
- Response Time:
- 1 sec
- Operating Pressure Differential - Minimum:
- 0 psi
- Operating Pressure Differential Cryogenic Fluid - Maximum:
- Not Applicable
- Coefficient of Volume (Cv):
- 0.21
- Valve Starting Configuration:
- Normally Closed
- Operating Pressure Differential Air/Inert Gas - Maximum:
- 500 psi
- Operating Pressure Differential Steam - Minimum:
- Not Applicable
- Operating Pressure Differential Natural Gas - Maximum:
- Not Applicable
- Frequency:
- 60 Hz
- Mounting Orientation:
- Horizontal or Vertical
- Package Quantity:
- 1