120V AC Aluminum Air and Fuel Gas Solenoid Valve, Normally Closed, 1/2 in Pipe Size - 8215G020

Redhat
SKU:
8215G020
|
UPC:
94700496096
Availability:
In Stock

Log in for pricing

(No reviews yet)
Current Stock:
Solenoid Valve, Valve Ways 2-Way, Valve Starting Configuration Normally Closed, Valve Type High Flow, Nominal Pipe Size 1/2 in, Orifice Diameter 3/4 in, Body Material Aluminum, Coefficient of Volume (Cv) 4.4, Operating Pressure Differential Air/Inert Gas - Maximum 50 psi, Operating Pressure Differential Fuel Gas - Maximum Not Applicable, Seal Material NBR, Voltage 110V AC, 120V AC, Operating Pressure Differential Fuel Oil - Maximum Not Applicable
Country of Origin:
Mexico
Pipe Size - Valves:
1/2 in
Center Line Pipe Center Size:
3 15/32 in
Electrical Connections:
18 Leads"
Valve Design:
2-Way/2-Position
Voltage:
120V AC
Item:
Air and Fuel Gas Solenoid Valve
Orifice Dia.:
3/4 in
Valve Configuration:
Normally Closed
Body Material - Valves:
Aluminum
Overall Height:
4 1/32 in
Overall Length:
2 3/4 in
Max. Fluid Temp.:
125 Degrees F
NEMA Rating:
1, 2, 3, 3S, 4, 4X
Body Material:
Aluminum
Environmental Rating - Valves:
Indoor, Outdoor
Pipe Size:
1/2";Coil Enclosure=General Purpose No Junction Box and Watertight"
Valve Ways and Positions:
2-Way/2-Position
BtuH:
238,500
Application:
Air and Vacuum Service
Watts:
10.1 W
Seal Material - Valves:
NBR
Max. Operating Pressure Differential:
50 psi
Overall Width:
2 23/64 in
Max. Operating Pressure Differential Air/Inert Gas:
50 psi
Seal Material:
NBR
Ambient Temp. Range:
32 Degrees to 125 Degrees F
Max. Operating Pressure Differential Water:
50 psi
Media:
Air/Fuel Gas
Min. Operating Pressure Differential:
0 psi
Hz:
50/60
Coefficient of Volume:
4.4
Standards:
CSA, FM, UL
Coil Insulation Class:
F
Operation Type:
Direct Acting
IP Rating:
IP65
Center Le Pipe Center Size:
3 15/32""
Includes Seal:
Yes
Operating Pressure Differential Fuel Gas - Minimum:
Not Applicable
Operating Pressure Differential Liquid CO2 - Minimum:
Not Applicable
Nominal Pipe Size:
1/2 in
Operating Pressure Differential Cryogenic Fluid - Maximum:
Not Applicable
Operating Pressure Differential Fuel Oil - Maximum:
Not Applicable
Valve Ways:
2-Way
Operating Pressure Differential - Minimum:
0 psi
Operating Pressure Differential Steam - Minimum:
Not Applicable
Operating Pressure Differential Water - Maximum:
50 psi
Operating Pressure Differential Natural Gas - Maximum:
Not Applicable
Valve Starting Configuration:
Normally Closed
Coefficient of Volume (Cv):
4.4
Thread Type:
NPT
Operating Pressure Differential Water - Minimum:
0 psi
Operating Pressure Differential Steam - Maximum:
Not Rated
Ambient Temperature - Maximum:
140 Degrees F
Includes Coil:
Yes
NEMA Enclosure Rating:
1, 2, 3, 3S, 4, 4X
Operating Pressure Differential Hot Water - Minimum:
Not Applicable
For Media:
Air, Inert Gases, Liquid Propane Gas, Natural Gas, Oxygen
Wattage:
10.1 W
Environmental Rating:
Hazardous, Indoor, Outdoor
Operating Pressure Differential Air/Inert Gas - Maximum:
50 psi
Operating Pressure Differential Light Oil - Minimum:
Not Applicable
Frequency:
50 Hz, 60 Hz
Fluid Temperature - Maximum:
125 Degrees F
Operating Pressure Differential Fuel Oil - Minimum:
Not Applicable
Operating Pressure Differential Cryogenic Fluid - Minimum:
Not Applicable
Outlet Connection Type:
NPTF
Orifice Diameter:
3/4 in
Operating Pressure Differential Liquid CO2 - Maximum:
Not Applicable
Ambient Temperature - Minimum:
14 Degrees F
Operating Pressure Differential Fuel Gas - Maximum:
Not Applicable
Gas Capacity:
238,500 BtuH
Operating Pressure Differential Air/Inert Gas - Minimum:
0 psi
Operating Pressure Differential Light Oil - Maximum:
Not Rated
Inlet Connection Type:
NPTF
Valve Type:
High Flow
Operating Pressure Differential Hot Water - Maximum:
Not Rated
Valve Positions:
2-Position
Operating Pressure Differential Natural Gas - Minimum:
Not Applicable
Response Time:
120 msec
Package Quantity:
1